Von/Voff Operation
You can set voltage value Von/Voff to control the input state on/off for electronic load. When the input voltage reaches the Von value, the load’s input state is on. When the input voltage reaches the Voff value, the load’s input state is off.
Action for set Von/Voff value:
(1) Press Shift + Menu into menu
(2) VFD displays >CONFIG, presskey to choose >SYSTEM SET, press Enter to confirm
(3) VFD displays >MAX CURRENT SET, presskey to choose>VOLTAGE ON SET, press Enter key to
confirm
(4) VFD displays >VOLT.ON=0.00V, press numeric keys to set Von value (0.1V to max voltage value), press Enter
(5) Presskey to choose >VOLTAGE OFF SET, press Enter to confirm
(6) VFD displays >VOLT.OFF=0.00V, press numeric keys to set Voff value (0V to max voltage value), press Enter