B&K 8510 instruction manual Table of Contents

Page 3

TABLE OF CONTENTS

QUICK REFERENCE

6

Location

22

The Front Panel

6

Installation

23

The Rear Panel

7

Bench Operation

23

Front Panel Display

7

Input Connections

23

Immediate Action Keys

8

Power Cord

23

Front Panel Menus

8

Trigger and Remote Sensing Connections

24

Key Pad

8

TURN-ON CHECKOUT

24

Menu Operation

9

Introduction

24

GENERAL INFORMATION

11

Checkout Procedure

24

Document Orientation

11

In Case of Trouble

25

Getting Started Map

11

FRONT PANEL OPERATION

25

Options and Accessories

11

Example

26

Options

11

I-set

26

Accessories

12

P-set

27

Description

12

R-set

27

Features and Capabilities

12

V-set

28

Front Panel Controls

12

Shift + Store

28

Remote Programming

13

Shift + Recall

28

Operating Modes

13

In On/Off input setting

28

Constant Current (CC) Mode

13

Transition Testing Operation

28

Constant Resistance (CR) Mode

13

Transition Parameter Setting

29

Constant Voltage (CV) Mode

13

Continuous Transient Operation

29

Constant Power (CW) Mode

14

Pulse Transient Operation

29

Transient Operation

14

Toggled Transient Operation

30

Continuous

14

List Operation

31

Pulse

15

Quick Recall Function

32

Trigger Mode

15

Automatic Testing Function of Electronic Load

32

List Operation

16

Edit the Testing File

32

Triggered Operation

16

Automatic Testing

34

Input Control

16

Select the Precision between Low Range & High Range. 35

Short On/Off

16

SPECIFICATIONS

35

Input On/Off

17

REMOTE OPERATION MODE

36

Operation Range

17

1 Communication Cable

36

Protection Features

17

2 Communication between Electronic Load and PC

37

Remote Sense Function

18

3 Frame Format

37

Saving and Recalling Settings

19

4 Communication Protocol

39

Battery Testing

20

SERVICE / WARRANTY INFORMATION

55

Von/Voff Operation

21

 

 

INSTALLATION

22

 

 

Inspection

22

 

 

Damage

22

 

 

Items Supplied

22

 

 

Cleaning

22

 

 

3

Image 3
Contents Instruction Manual Programmable DC Electronic Load Table of Contents Warranty Information Safety Symbols Front Panel Quick ReferenceFront Panel Display Rear PanelTran Immediate Action KeysFront Panel Menus Key PadMenu Operation POWER-ON RecallADC Update Rate High Lowdefault Getting Started Map Options and AccessoriesGeneral Information Document OrientationFront Panel Controls Features and CapabilitiesAccessories DescriptionOperating Modes Constant Resistance CR ModeConstant Voltage CV Mode Remote ProgrammingConstant Power CW Mode Transient OperationContinuous Trigger Mode List OperationPulse Triggered Operation Input ControlShort On/Off Over Voltage Protection FeaturesInput On/Off Operation RangeRemote Sense Function and Trigger Function Over PowerOver Temperature Pin trigger and remote sensing connectorsWiring diagram for remote sense Saving and Recalling SettingsOperation Battery TestingAction for set Von/Voff value Von/Voff OperationInstallation InspectionLocation Input Connections Power CordOutline Diagram Bench OperationTrigger and Remote Sensing Connections Checkout ProcedureTurn-On Checkout IntroductionFront Panel Display Front Panel OperationCase of Trouble DisplayFunction keys PowerSet set up a constant current from 0 to Max current Example000V Set set up a constant power from 0 to Max powerSet set up a constant resistance from 0.1Ω to 4000Ω POWER=*.***WShift + Store Transition Testing OperationSet set up a constant voltage from 1.5V to Max voltage On/Off input settingTransition Parameter Setting Continuous Transient OperationPulse Transient Operation Steps Toggled Transient OperationList Operation Automatic Testing Function of Electronic Load Edit the Testing FileQuick Recall Function Enter Setting the Resolution and number of decimal points Automatic TestingRange Accuracy Resolution SpecificationsIT-E132 USB Communication cable Remote Operation ModeCommunication cable IT-E131 RS232 Communication cableCommunication between electronic load and PC Frame FormatIT-E132 communication 2AH Communication Protocol Selecting the Remote control mode(20H)Setting / Reading max input voltage(22H/23H) Setting / Reading the max input current .(24H/25H)Selecting the input on/off state (21H) Setting / Reading max input power(26H/27H) Setting / Reading CC mode current value(2AH/2BH) Setting / Reading CV mode voltage value.(2CH/2DH)Setting / Reading CW mode watt value(2EH/2FH) Setting / Reading CR mode resistance value(30H/31H) 26th byte Sum code Setting / Reading the number of list steps EH/3FH Setting /Reading the list repeat mode CH/3DHSetting / Reading List file name 48H/49H Save / Get list file in appointed area. CH/4DH Setting / Reading timer value of for Load on 50H/51H)Setting communication address 54H Enable/Disable Local control mode HSelecting / Reading trigger source H/59H Reading input voltage, current, power and relative state FH Sending a trigger signal to trigging the electronic load AHBIT Enter the calibration mode(60H)Calibrate voltage value(62H) Getting the calibration mode state(61H)Setting / Reading calibration information(67H/68H) Calibrate current value(64H)Store the calibration data to EEPROM(66H) Restore the factory default calibration data(69H) For example:Reading information in bar code 6BH Setting information of bar code(6CH) Limited One-Year Warranty Service InformationDeclaration of CE Conformity Savi Ranch Parkway Yorba Linda, CA