Lincoln Electric IM584-D manual DIP Switch Setup, Setting DIP Switches in the Control BOX

Page 15

A-7

INSTALLATION

A-7

 

 

 

DIP SWITCH SETUP

SETTING DIP SWITCHES IN THE CONTROL BOX

There are two DIP switch banks on the mother board of the Control Box. They are labeled S1 and S2 and are located and oriented as shown in Figure A.3.

ON

 

 

 

 

 

 

 

 

S1

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

S2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FIGURE A.3

S2 DIP Switch Bank on Control Box Motherboard (For software version S24004-2 only)

Switch

Off

 

On

 

 

 

 

1

Network Group ID, MSB

(Assigns Control Box to a specific group) (Off is factory setting)

 

 

 

 

2

Network Group ID, LSB

(Assigns Control Box to a specific group ) (Off is factory setting)

3Spare

4Spare

5Spare

6Spare

7Spare

8Reserved

S1 DIP Switch Bank on Control Box Motherboard (For software version S24004-3 & up)

 

Switch

Off

 

On

 

 

 

 

 

 

1

Standard speed gearbox limits adjustable

High speed gearbox limits adjustable

 

 

 

 

 

 

2

WFS Display = inches/minute

WFS Display = meters/minute

 

 

 

 

 

 

3

Left Display is always preset WFS

Left Display is preset WFS when weld current is not flowing

 

 

 

 

 

Left Display is actual weld current when weld current is flowing

 

 

 

 

 

 

 

 

CC modes override this switch regardless of position. Left Display is always preset weld cur-

 

 

 

rent when weld current is not flowing and actual weld current when weld current is flowing

 

 

 

 

 

 

4

Run-in = Minimum Speed Available

Run-in = weld WFS

 

 

 

 

 

 

 

 

If any option containing a Run-in setting is connected to the motherboard, it automatically

 

 

 

overrides this switch regardless of position.

 

5

Memory change with trigger disabled

Memory change with trigger enabled

 

 

 

 

 

 

 

6

Acceleration, MSB

(Sets acceleration rate for wire drive) see below

 

 

 

 

 

 

7

Acceleration

(Sets acceleration rate for wire drive) see below

 

 

 

 

 

 

8

Acceleration, LSB

(Sets acceleration rate for wire drive) see below

 

 

 

 

 

 

 

Note: the factory shipped settings for all of the S1 and S2 switches is “OFF”.

POWER FEED 10

Image 15
Contents OPERATOR’S Manual California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Section E Section FP306 Series Installation Safety Precautions Mounting the Wire Drive UnitBoom Mounting of Wire Drive Unit Control Cable Connections Mounting on Power SourceControl Cable Mounting the Control BOX Boom or Separated Bench ModelsControl Cable Specifications Available Cable AssembliesElectrode Cable Connections Selecting the Proper Gear Ratio Wire Drive Gear Ratio High or LOW SpeedChanging the Wire Drive Ratio Work Cable ConnectionsRatio Change Procedure Setting DIP Switches in the Control BOX DIP Switch Setup8INSTALLATIONA-8 LSB Figure A.4 Setting DIP Switches in the Wire DriveGUN and Cable Assemblies with FAST-MATECONNECTION Wire Feed Drive Roll KitsProcedure to Install Drive Rolls and Wire Guides GUN and Cable Assemblies with Standard ConnectionGUN Connections General General GUN Connection GuidelinesWater Connections for Water Cooled Guns Wire Spindle PlacementWire Feed Shut Down Circuit Optional Gmaw Shielding GASGeneral Panel Installation Guidelines Boom and Bench ConversionsOptional Panels for Control BOX Duty Cycle OperationProduct Description Recommended Processes and EquipmentK1542-9 Dual Procedure / Memory Panel K1542-5 Dual Procedure PanelK1542-11 MX2 Panel Control BOX Panels -- ʻLARGEʼ Option PanelsCV/Gouge PanelStd K1542-6 M PanelK1542-12 MSP2 Panel Control BOX Panels -- SET UP Controls DescriptionControl BOX -- PC Board Adjustments Control BOX -- Using Operating LimitsWire Drive Operation Wire Drive Settings -- ExternalOperation with Previous Software Version Wire Reel Loading READI-REELS, Spools or Coils Electrode PolarityGear BOX Ratio Figure B.1 GAS Guard Regulator Setting Feeding Electrode and Brake AdjustmentDrive Roll Pressure Setting Procedure for Setting Angle of FeedplateWire Reel Changing Wire Feed Overload ProtectionMaking a Weld Status Light States Component Status LightsStatus Light States CONʼT Aluminum Electrode AccessoriesWire Size Solid Steel Electrode Cored ElectrodeK1542-5 Dual Procedure Panel Description and Installation of Optional Control BOX PanelsConstant Voltage CV/Weld, CV/MIG, CV/Flux Cored Procedures CC/STICK/GOUGE ModeK1542-11 MX2 Panel Large Panel 10 MS/STT Panel Large Panel K1542-9 Dual Procedure Memory Panel Small Panel K1543, K1544 and K1545 Input Cable Assemblies Control Box Cabinet Procedure Feeder Head Enclosure ProcedureK1548-1 Linc NET Receptacle KIT Input and Output K363P READI-REEL Adapter K162H Wire Spindle AdapterK1504-1 Coil Adapter K435 Coil AdapterGUN Receiver Bushings and Adapters Guns and GUN AdaptersDual Procedure Switch Options Using Dual Procedure with FAST-MATE GunsConduit Adapters K1557-1 Swivel Mount K590-5 Water Connection KIT for Drive onlyK1536-1 Water Flow Sensor KIT K659-1 GAS Guard RegulatorGun and Cable Maintenance MaintenanceMaintenance Wire Drive Motor and GearboxHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Troubleshooting Possible Cause Recommended Symptoms Course of Action Field Service FacilityYour local Lincoln Authorized Troubleshooting Course of Action Possible CauseEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Switch 8 must be set to 1 or ON. Field Service Facility Err 005 Err 001Err 003 Err 004Err 201 Err 020Err 100 Err 200Err 212 Err 211Diagrams Wiring Diagram Power Feed 10 Wire Drive Diagrams2000 L10599 Power FeedPower Feed Power Feed Power Feed Precaucion Warnung