Lincoln Electric IM584-D K590-5 Water Connection KIT for Drive only, K659-1 GAS Guard Regulator

Page 46

C-12

ACCESSORIES

C-12

 

 

 

K590-5 WATER CONNECTION KIT (FOR DRIVE ONLY)

Install per the instructions shipped with the kit.

K1536-1 WATER FLOW SENSOR KIT

Install per the instructions shipped with the kit

K659-1 GAS GUARD REGULATOR

Adjustable flow regulator with removable adjuster key for CO2 and Argon blend gases. Mounts onto feeder inlet, and reduces gas waste and arc start “blow” by reducing surge caused by excess pressure in supply hose.

Install the 5/8-18 male outlet of the regulator to the 5/8-18 female gas inlet on the back panel of the wire drive. Secure fitting with flow adjuster key at top. Attach gas supply to 5/8-18 female inlet of regulator per INSTALLATION section.

K1557-1 SWIVEL MOUNT

The K1557-1 Swivel mount attaches to the power source. This kit includes a feeder adapter plate that allows the feeder to rotate on top of the power source. The feeder can be easily separated from the swivel mount at any time. This option is compatible with the K1556-1 Light Duty Caster Kit.

K1556-1 LIGHT DUTY CASTER KIT

This option provides 4 casters and all required hard- ware to mount it to the Power Feed 10. This option is compatible with the K1557-1 Swivel Mount.

K1574-1 SECURITY DOOR (LARGE)

K1574-1 Security Door Installation into the Control Box Cabinet

1.Turn off power.

2.Unlatch and swing open the small door. Remove the two screws from the horizontal hinge rod. Save the screws.

3.While holding the door so it doesnʼt fall, Slide the rod out sideways releasing the door.

4.Position the new door between the panel holes and re-install the rod so the screw holes can be accessed.

5.Replace the two screws and tighten.

6.Swing the door into the up position. A lock may be installed through the side holes for security purposes.

K1555-1 INSULATED LIFT HOOK

For applications where an insulated lift hook is required. This kit provides an easily installed, heavy duty insulated lift eye that mounts to the wire reel stand mast. See the instructions provided with the kit for installation.

K1551-2 INCOMING BUSHING

(4 Ball Roller) (Standard on codes 10600 and up)

This ball bearing equipped incoming bushing can be used in place of the standard incoming wire bushing, when feeding solid steel or cored wire electrodes. It significantly reduces any abrasion to the electrode wire where it enters the feed head. This results in even smoother, more trouble free operation.

POWER FEED 10

Image 46
Contents OPERATOR’S Manual Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Section F Section EP306 Series Installation Mounting the Wire Drive Unit Safety PrecautionsBoom Mounting of Wire Drive Unit Mounting the Control BOX Boom or Separated Bench Models Mounting on Power SourceControl Cable Control Cable ConnectionsAvailable Cable Assemblies Control Cable SpecificationsElectrode Cable Connections Work Cable Connections Wire Drive Gear Ratio High or LOW SpeedChanging the Wire Drive Ratio Selecting the Proper Gear RatioRatio Change Procedure DIP Switch Setup Setting DIP Switches in the Control BOX8INSTALLATIONA-8 LSB Setting DIP Switches in the Wire Drive Figure A.4GUN and Cable Assemblies with Standard Connection Wire Feed Drive Roll KitsProcedure to Install Drive Rolls and Wire Guides GUN and Cable Assemblies with FAST-MATECONNECTIONGeneral GUN Connection Guidelines GUN Connections GeneralGmaw Shielding GAS Wire Spindle PlacementWire Feed Shut Down Circuit Optional Water Connections for Water Cooled GunsBoom and Bench Conversions General Panel Installation GuidelinesOptional Panels for Control BOX Recommended Processes and Equipment OperationProduct Description Duty CycleK1542-5 Dual Procedure Panel K1542-9 Dual Procedure / Memory PanelK1542-6 M Panel Control BOX Panels -- ʻLARGEʼ Option PanelsCV/Gouge PanelStd K1542-11 MX2 PanelControl BOX Panels -- SET UP Controls Description K1542-12 MSP2 PanelControl BOX -- Using Operating Limits Control BOX -- PC Board AdjustmentsWire Drive Settings -- External Wire Drive OperationOperation with Previous Software Version Electrode Polarity Wire Reel Loading READI-REELS, Spools or CoilsGear BOX Ratio Figure B.1 Procedure for Setting Angle of Feedplate Feeding Electrode and Brake AdjustmentDrive Roll Pressure Setting GAS Guard Regulator SettingWire Feed Overload Protection Wire Reel ChangingMaking a Weld Component Status Lights Status Light StatesStatus Light States CONʼT Cored Electrode AccessoriesWire Size Solid Steel Electrode Aluminum ElectrodeDescription and Installation of Optional Control BOX Panels K1542-5 Dual Procedure PanelCC/STICK/GOUGE Mode Constant Voltage CV/Weld, CV/MIG, CV/Flux Cored ProceduresK1542-11 MX2 Panel Large Panel 10 MS/STT Panel Large Panel K1542-9 Dual Procedure Memory Panel Small Panel K1543, K1544 and K1545 Input Cable Assemblies Feeder Head Enclosure Procedure Control Box Cabinet ProcedureK1548-1 Linc NET Receptacle KIT Input and Output K435 Coil Adapter K162H Wire Spindle AdapterK1504-1 Coil Adapter K363P READI-REEL AdapterGuns and GUN Adapters GUN Receiver Bushings and AdaptersUsing Dual Procedure with FAST-MATE Guns Dual Procedure Switch OptionsConduit Adapters K659-1 GAS Guard Regulator K590-5 Water Connection KIT for Drive onlyK1536-1 Water Flow Sensor KIT K1557-1 Swivel MountWire Drive Motor and Gearbox MaintenanceMaintenance Gun and Cable Maintenance1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideTroubleshooting Field Service Facility Possible Cause Recommended Symptoms Course of ActionYour local Lincoln Authorized Troubleshooting Possible Cause Course of ActionEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Switch 8 must be set to 1 or ON. Field Service Facility Err 004 Err 001Err 003 Err 005Err 200 Err 020Err 100 Err 201Err 211 Err 212Diagrams Diagrams Wiring Diagram Power Feed 10 Wire DrivePower Feed 2000 L10599Power Feed Power Feed Power Feed Precaucion Warnung