Lincoln Electric IM584-D manual Lsb

Page 17

A-9

INSTALLATION

A-9

 

 

 

S1 DIP Switch Bank on Control Box Motherboard (For software version S24456)

 

Switch

Off

 

On

 

 

 

 

 

 

1

Standard speed gearbox limits adjustable

High speed gearbox limits adjustable

 

 

 

 

 

 

2

WFS Display = inches/minute

WFS Display = meters/minute

 

 

 

 

 

 

3

Left Display is always preset WFS

Left Display is preset WFS when weld current is not flowing

 

 

 

 

 

Left Display is actual weld current when weld current is flowing

 

 

 

 

 

 

 

 

CC modes override this switch regardless of position. Left Display is always preset weld cur-

 

 

 

rent when weld current is not flowing and actual weld current when weld current is flowing

 

 

 

 

 

 

4

Run-in = Minimum Speed Available

Run-in = weld WFS

 

 

 

 

 

 

 

 

If any option containing a Run-in setting is connected to the motherboard, it automatically

 

 

 

overrides this switch regardless of position.

 

5

Memory change with trigger disabled

Memory change with trigger enabled

 

 

 

 

 

 

 

6

Acceleration, MSB

(Sets acceleration rate for wire drive) see below

 

 

 

 

 

 

7

Acceleration

(Sets acceleration rate for wire drive) see below

 

 

 

 

 

 

8

Acceleration, LSB

(Sets acceleration rate for wire drive) see below

 

 

 

 

 

 

 

Note: the factory shipped settings for the S1 switches are as follows:

PF-10 (and Dual) Domestic - All switches “OFF”

PF-10 (and Dual) European - switches 1 & 3-8 “OFF”, 2 “ON”

PF-11 Domestic - switches 2-8 “OFF”, 1 “ON”

PF-11 European - switches 3-8 “OFF”, 1,2 “ON”

 

 

 

S2 DIP Switch Bank on Control Box Motherboard (For software version S24456)

 

 

 

 

 

Switch

Off

 

 

On

 

 

 

 

1

Network Group ID, MSB

(Assigns Control Box to a specific group) (Off is factory setting)

 

 

 

 

2

Network Group ID, LSB

(Assigns Control Box to a specific group ) (Off is factory setting)

 

 

 

 

3

4-Step Domestic Configuration

 

4-Step European Configuration

 

 

 

 

 

4

Power Feed 10 / Dual

 

 

Power Feed 11

 

 

 

5

Procedure Change with Trigger “OFF”

Procedure Change with Trigger “ON”

 

 

 

 

 

6

Set lower limits

 

 

 

 

 

 

 

 

7

Set upper limits

 

 

 

 

 

 

8

Must be on for all units (Permits selection of extended modes)

 

 

 

 

 

Note: the factory shipped settings for the S2 switches are as follows:

PF-10

(and Dual) Domestic - switches 1-7

“OFF”, 8 “ON”

PF-10

(and Dual) European - switches 1,2,4-7 “OFF”, 3,8 “ON”

PF-11

Domestic - switches 1-3,5-7 “OFF”,

4,8 “ON”

PF-11

European - switches 1,2,5-7 “OFF”, 3,4,8 “ON”

MSB - Most Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the left.

LSB -

Least Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the right.

POWER FEED 10

Image 17
Contents OPERATOR’S Manual California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents P306 Series Section ESection F Installation Boom Mounting of Wire Drive Unit Safety PrecautionsMounting the Wire Drive Unit Control Cable Mounting on Power SourceMounting the Control BOX Boom or Separated Bench Models Control Cable ConnectionsElectrode Cable Connections Control Cable SpecificationsAvailable Cable Assemblies Changing the Wire Drive Ratio Wire Drive Gear Ratio High or LOW SpeedWork Cable Connections Selecting the Proper Gear RatioRatio Change Procedure Setting DIP Switches in the Control BOX DIP Switch Setup8INSTALLATIONA-8 LSB Figure A.4 Setting DIP Switches in the Wire DriveProcedure to Install Drive Rolls and Wire Guides Wire Feed Drive Roll KitsGUN and Cable Assemblies with Standard Connection GUN and Cable Assemblies with FAST-MATECONNECTIONGUN Connections General General GUN Connection GuidelinesWire Feed Shut Down Circuit Optional Wire Spindle PlacementGmaw Shielding GAS Water Connections for Water Cooled GunsOptional Panels for Control BOX General Panel Installation GuidelinesBoom and Bench Conversions Product Description OperationRecommended Processes and Equipment Duty CycleK1542-9 Dual Procedure / Memory Panel K1542-5 Dual Procedure PanelCV/Gouge PanelStd Control BOX Panels -- ʻLARGEʼ Option PanelsK1542-6 M Panel K1542-11 MX2 PanelK1542-12 MSP2 Panel Control BOX Panels -- SET UP Controls DescriptionControl BOX -- PC Board Adjustments Control BOX -- Using Operating LimitsOperation with Previous Software Version Wire Drive OperationWire Drive Settings -- External Gear BOX Ratio Wire Reel Loading READI-REELS, Spools or CoilsElectrode Polarity Figure B.1 Drive Roll Pressure Setting Feeding Electrode and Brake AdjustmentProcedure for Setting Angle of Feedplate GAS Guard Regulator SettingMaking a Weld Wire Reel ChangingWire Feed Overload Protection Status Light States Component Status LightsStatus Light States CONʼT Wire Size Solid Steel Electrode AccessoriesCored Electrode Aluminum ElectrodeK1542-5 Dual Procedure Panel Description and Installation of Optional Control BOX PanelsConstant Voltage CV/Weld, CV/MIG, CV/Flux Cored Procedures CC/STICK/GOUGE ModeK1542-11 MX2 Panel Large Panel 10 MS/STT Panel Large Panel K1542-9 Dual Procedure Memory Panel Small Panel K1543, K1544 and K1545 Input Cable Assemblies K1548-1 Linc NET Receptacle KIT Input and Output Control Box Cabinet ProcedureFeeder Head Enclosure Procedure K1504-1 Coil Adapter K162H Wire Spindle AdapterK435 Coil Adapter K363P READI-REEL AdapterGUN Receiver Bushings and Adapters Guns and GUN AdaptersConduit Adapters Dual Procedure Switch OptionsUsing Dual Procedure with FAST-MATE Guns K1536-1 Water Flow Sensor KIT K590-5 Water Connection KIT for Drive onlyK659-1 GAS Guard Regulator K1557-1 Swivel MountMaintenance MaintenanceWire Drive Motor and Gearbox Gun and Cable MaintenanceHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Troubleshooting Your local Lincoln Authorized Possible Cause Recommended Symptoms Course of ActionField Service Facility Troubleshooting Course of Action Possible CauseEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Switch 8 must be set to 1 or ON. Field Service Facility Err 003 Err 001Err 004 Err 005Err 100 Err 020Err 200 Err 201Err 212 Err 211Diagrams Wiring Diagram Power Feed 10 Wire Drive Diagrams2000 L10599 Power FeedPower Feed Power Feed Power Feed Precaucion Warnung