INSTALLATION |
Setting Wire Drive Acceleration Rate Using | (All software versions) | ||
DIP Switch S1 on the Control Box Motherboard |
|
| |
| DIP SWITCH 6 | DIP SWITCH 7 | DIP SWITCH 8 |
|
|
|
|
Acceleration 1 (slow) | Off | Off | On |
|
|
|
|
Acceleration 2 | Off | On | Off |
|
|
|
|
Acceleration 3 | Off | On | On |
|
|
|
|
Acceleration 4 | On | Off | Off |
|
|
|
|
Acceleration 5 (fast ) (factory setting) | Off | Off | Off |
|
|
|
|
SETTING DIP SWITCHES IN THE WIRE DRIVE
There is one DIP switch bank on the control board of the wire drive. Itʼs labeled S1 and is located and ori- ented as shown in Figure A.4.
ON
1 2 3 4 5 6 7 8
S1
FIGURE A.4
S1 DIP Switch on Wire Drive Control Board (For software version
Switch | Off |
|
| On |
|
|
|
| |
1 | Network Group ID, MSB | (Assigns Wire Drive to a specific group) | ||
|
|
|
| |
2 | Network Group ID, LSB | (Assigns Wire Drive to a specific group ) | ||
|
|
|
| |
3 | Network Feed Head ID, MSB | (Assigns feed head number to wire drive) | ||
|
|
|
|
|
4 | Network Feed Head ID |
| (Assigns feed head number to wire drive) | |
|
|
|
| |
5 | Network Feed Head ID, LSB | (Assigns feed head number to wire drive) | ||
6Spare
7 | Electrode Sense Polarity = Positive | Electrode Sense Polarity = Negative |
|
|
|
|
|
|
| Switch position must match polarity of weld cable attached to feed plate. | |
8
Gear Box Ratio = Low
Gear Box Ratio = High
Switch position must match actual gear box ratio of wire drive.
Note: the factory shipped settings for all of the S1 switches is “OFF”.
POWER FEED 10