Lincoln Electric IM584-D Feeding Electrode and Brake Adjustment, Drive Roll Pressure Setting

Page 31

B-9

OPERATION

B-9

 

 

 

FEEDING ELECTRODE AND BRAKE ADJUSTMENT

1)Turn the Reel or spool until the free end of the electrode is accessible.

2)While tightly holding the electrode, cut off the bent end and straighten the first 6" (150 mm). Cut off the first 1" (25 mm). (If the electrode is not proper- ly straightened, it may not feed or may jam causing a "birdnest".)

3)Insert the free end through the incoming guide tube.

4)Press the Cold Inch key or the Cold Feed Mode gun trigger and push the electrode into the drive roll.

WARNING

When feeding with the gun trigger, unless “COLD FEED” trigger mode is selected, the electrode and drive mechanism are always “HOT” to work and ground and could remain “HOT” several seconds after the gun trigger is released.

___________________________________________

5)Feed the electrode through the gun.

6)Adjust the brake tension with the thumbscrew on the spindle hub, until the reel turns freely but with little or no overrun when wire feeding is stopped. Do not overtighten.

DRIVE ROLL PRESSURE SETTING

The Power Feed 10 pressure is factory pre-set to about position “2” as shown on the pressure indicator on the front of the feedplate door. This is an approxi- mate setting.

The optimum drive roll pressure varies with type of wire, surface condition, lubrication, and hardness. Too much pressure could cause “birdnesting”, but too little pressure could cause wire feed slippage with load and/or acceleration. The optimum drive roll set- ting can be determined as follows:

1)Press end of gun against a solid object that is electrically isolated from the welder output and press the gun trigger for several seconds.

2)If the wire "birdnests", jams, or breaks at the drive roll, the drive roll pressure is too great. Back the pressure setting out turn, run new wire through gun, and repeat above steps.

3)If the only result is drive roll slippage, disengage the gun, pull the gun cable forward about 6" (150 mm). There should be a slight waviness in the exposed wire. If there is no waviness, the pres- sure is too low. Increase the pressure setting turn, reconnect the gun, tighten locking clamp and repeat the above steps.

PROCEDURE FOR SETTING ANGLE OF FEEDPLATE

1)Loosen the clamping collar screw using a 3/16" Allen wrench. The clamping collar screw is accessed from the bottom of the feedplate. It is the screw which is perpendicular to the feeding direction.

2)Rotate feedplate to the desired angle and tighten clamping collar screw.

GAS GUARD REGULATOR SETTING

1)With the gas supply shut off, the Gas Guard regu- lator flow adjusting Key should be set to maximum (full clockwise) which is rated to be 60 SCFH (28 l/min).

2)Adjust gas supply flow rate for a level higher than will be required, then adjust Gas Guard flow adjusting Key counterclockwise to the desired gas flow rate.

POWER FEED 10

Image 31
Contents OPERATOR’S Manual California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Section F Section EP306 Series Installation Mounting the Wire Drive Unit Safety PrecautionsBoom Mounting of Wire Drive Unit Control Cable Connections Mounting on Power SourceControl Cable Mounting the Control BOX Boom or Separated Bench ModelsAvailable Cable Assemblies Control Cable SpecificationsElectrode Cable Connections Selecting the Proper Gear Ratio Wire Drive Gear Ratio High or LOW SpeedChanging the Wire Drive Ratio Work Cable ConnectionsRatio Change Procedure Setting DIP Switches in the Control BOX DIP Switch Setup8INSTALLATIONA-8 LSB Figure A.4 Setting DIP Switches in the Wire DriveGUN and Cable Assemblies with FAST-MATECONNECTION Wire Feed Drive Roll KitsProcedure to Install Drive Rolls and Wire Guides GUN and Cable Assemblies with Standard ConnectionGUN Connections General General GUN Connection GuidelinesWater Connections for Water Cooled Guns Wire Spindle PlacementWire Feed Shut Down Circuit Optional Gmaw Shielding GASBoom and Bench Conversions General Panel Installation GuidelinesOptional Panels for Control BOX Duty Cycle OperationProduct Description Recommended Processes and EquipmentK1542-9 Dual Procedure / Memory Panel K1542-5 Dual Procedure PanelK1542-11 MX2 Panel Control BOX Panels -- ʻLARGEʼ Option PanelsCV/Gouge PanelStd K1542-6 M PanelK1542-12 MSP2 Panel Control BOX Panels -- SET UP Controls DescriptionControl BOX -- PC Board Adjustments Control BOX -- Using Operating LimitsWire Drive Settings -- External Wire Drive OperationOperation with Previous Software Version Electrode Polarity Wire Reel Loading READI-REELS, Spools or CoilsGear BOX Ratio Figure B.1 GAS Guard Regulator Setting Feeding Electrode and Brake AdjustmentDrive Roll Pressure Setting Procedure for Setting Angle of FeedplateWire Feed Overload Protection Wire Reel ChangingMaking a Weld Status Light States Component Status LightsStatus Light States CONʼT Aluminum Electrode AccessoriesWire Size Solid Steel Electrode Cored ElectrodeK1542-5 Dual Procedure Panel Description and Installation of Optional Control BOX PanelsConstant Voltage CV/Weld, CV/MIG, CV/Flux Cored Procedures CC/STICK/GOUGE ModeK1542-11 MX2 Panel Large Panel 10 MS/STT Panel Large Panel K1542-9 Dual Procedure Memory Panel Small Panel K1543, K1544 and K1545 Input Cable Assemblies Feeder Head Enclosure Procedure Control Box Cabinet ProcedureK1548-1 Linc NET Receptacle KIT Input and Output K363P READI-REEL Adapter K162H Wire Spindle AdapterK1504-1 Coil Adapter K435 Coil AdapterGUN Receiver Bushings and Adapters Guns and GUN AdaptersUsing Dual Procedure with FAST-MATE Guns Dual Procedure Switch OptionsConduit Adapters K1557-1 Swivel Mount K590-5 Water Connection KIT for Drive onlyK1536-1 Water Flow Sensor KIT K659-1 GAS Guard RegulatorGun and Cable Maintenance MaintenanceMaintenance Wire Drive Motor and GearboxHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Troubleshooting Field Service Facility Possible Cause Recommended Symptoms Course of ActionYour local Lincoln Authorized Troubleshooting Course of Action Possible CauseEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Switch 8 must be set to 1 or ON. Field Service Facility Err 005 Err 001Err 003 Err 004Err 201 Err 020Err 100 Err 200Err 212 Err 211Diagrams Wiring Diagram Power Feed 10 Wire Drive Diagrams2000 L10599 Power FeedPower Feed Power Feed Power Feed Precaucion Warnung