Lincoln Electric IM584-D manual 1TROUBLESHOOTINGE-1, HOW to USE Troubleshooting Guide

Page 48

E-1TROUBLESHOOTINGE-1

HOW TO USE TROUBLESHOOTING GUIDE

WARNING

Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your safety and to avoid Electrical Shock, please observe all safety notes and precautions detailed throughout this manual.

__________________________________________________________________________

This Troubleshooting Guide is provided to help you locate and repair possible machine malfunctions. Simply follow the three-step procedure listed below.

Step 1. LOCATE PROBLEM (SYMPTOM). Look under the column labeled “PROBLEM (SYMPTOMS)”. This column describes possible symptoms that the machine may exhibit. Find the listing that best describes the symptom that the machine is exhibiting.

Step 2. POSSIBLE CAUSE.

The second column labeled “POSSIBLE CAUSE” lists the obvious external possibili- ties that may contribute to the machine symptom.

Step 3. RECOMMENDED COURSE OF ACTION

This column provides a course of action for the Possible Cause, generally it states to contact you local Lincoln Authorized Field Service Facility.

If you do not understand or are unable to perform the Recommended Course of Action safely, contact you local Lincoln Authorized Field Service Facility.

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

When inching with gun trigger, electrode and drive mechanism are “hot” to work and ground and could remain energized several seconds after the gun trigger is released.

Turn OFF input power at welding power source before installation or changing drive roll and/or guide tubes.

Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.

Only qualified personnel should perform these trouble shooting procedures.

Observe all additional Safety Guidelines detailed throughout this manual.

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

POWER FEED 10

Image 48
Contents OPERATOR’S Manual Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents Section E Section FP306 Series Installation Safety Precautions Mounting the Wire Drive UnitBoom Mounting of Wire Drive Unit Mounting on Power Source Control CableMounting the Control BOX Boom or Separated Bench Models Control Cable ConnectionsControl Cable Specifications Available Cable AssembliesElectrode Cable Connections Wire Drive Gear Ratio High or LOW Speed Changing the Wire Drive RatioWork Cable Connections Selecting the Proper Gear RatioRatio Change Procedure DIP Switch Setup Setting DIP Switches in the Control BOX8INSTALLATIONA-8 LSB Setting DIP Switches in the Wire Drive Figure A.4Wire Feed Drive Roll Kits Procedure to Install Drive Rolls and Wire GuidesGUN and Cable Assemblies with Standard Connection GUN and Cable Assemblies with FAST-MATECONNECTIONGeneral GUN Connection Guidelines GUN Connections GeneralWire Spindle Placement Wire Feed Shut Down Circuit OptionalGmaw Shielding GAS Water Connections for Water Cooled GunsGeneral Panel Installation Guidelines Boom and Bench ConversionsOptional Panels for Control BOX Operation Product DescriptionRecommended Processes and Equipment Duty CycleK1542-5 Dual Procedure Panel K1542-9 Dual Procedure / Memory PanelControl BOX Panels -- ʻLARGEʼ Option Panels CV/Gouge PanelStdK1542-6 M Panel K1542-11 MX2 PanelControl BOX Panels -- SET UP Controls Description K1542-12 MSP2 PanelControl BOX -- Using Operating Limits Control BOX -- PC Board AdjustmentsWire Drive Operation Wire Drive Settings -- ExternalOperation with Previous Software Version Wire Reel Loading READI-REELS, Spools or Coils Electrode PolarityGear BOX Ratio Figure B.1 Feeding Electrode and Brake Adjustment Drive Roll Pressure SettingProcedure for Setting Angle of Feedplate GAS Guard Regulator SettingWire Reel Changing Wire Feed Overload ProtectionMaking a Weld Component Status Lights Status Light StatesStatus Light States CONʼT Accessories Wire Size Solid Steel ElectrodeCored Electrode Aluminum ElectrodeDescription and Installation of Optional Control BOX Panels K1542-5 Dual Procedure PanelCC/STICK/GOUGE Mode Constant Voltage CV/Weld, CV/MIG, CV/Flux Cored ProceduresK1542-11 MX2 Panel Large Panel 10 MS/STT Panel Large Panel K1542-9 Dual Procedure Memory Panel Small Panel K1543, K1544 and K1545 Input Cable Assemblies Control Box Cabinet Procedure Feeder Head Enclosure ProcedureK1548-1 Linc NET Receptacle KIT Input and Output K162H Wire Spindle Adapter K1504-1 Coil AdapterK435 Coil Adapter K363P READI-REEL AdapterGuns and GUN Adapters GUN Receiver Bushings and AdaptersDual Procedure Switch Options Using Dual Procedure with FAST-MATE GunsConduit Adapters K590-5 Water Connection KIT for Drive only K1536-1 Water Flow Sensor KITK659-1 GAS Guard Regulator K1557-1 Swivel MountMaintenance MaintenanceWire Drive Motor and Gearbox Gun and Cable Maintenance1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideTroubleshooting Possible Cause Recommended Symptoms Course of Action Field Service FacilityYour local Lincoln Authorized Troubleshooting Possible Cause Course of ActionEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Switch 8 must be set to 1 or ON. Field Service Facility Err 001 Err 003Err 004 Err 005Err 020 Err 100Err 200 Err 201Err 211 Err 212Diagrams Diagrams Wiring Diagram Power Feed 10 Wire DrivePower Feed 2000 L10599Power Feed Power Feed Power Feed Precaucion Warnung