A-8 INSTALLATIONA-8
S2 DIP Switch Bank on Control Box Motherboard (For software version
Switch | Off |
| On |
|
|
|
|
1 | Network Group ID, MSB | (Assigns Control Box to a specific group) (Off is factory setting) | |
|
|
|
|
2 | Network Group ID, LSB | (Assigns Control Box to a specific group ) (Off is factory setting) | |
|
|
|
|
3 | Spare |
|
|
|
|
|
|
4 | Spare |
|
|
|
|
|
|
5 | Spare |
|
|
|
|
| |
6 | Must be off for normal operation | Adjust lower limits | |
|
|
| |
7 | Must be off for normal operation | Adjust upper limits | |
|
|
| |
8 | Must be on for European units only |
| |
|
|
|
|
S1 DIP Switch Bank on Control Box Motherboard (For software version
| Switch | Off | On |
|
|
|
|
|
|
1 | US | Euro |
| |
|
|
|
|
|
2 | WFS Display = inches/minute | WFS Display = meters/minute |
| |
|
|
|
|
|
3 | Left Display is always preset WFS | Left Display is preset WFS when weld current is not flowing |
| |
|
|
| Left Display is actual weld current when weld current is flowing |
|
|
|
|
|
|
|
| CC modes override this switch regardless of position. Left Display is always preset weld cur- |
| |
|
| rent when weld current is not flowing and actual weld current when weld current is flowing |
| |
|
|
|
| |
4 |
| |||
|
|
|
|
|
|
| If any option containing a |
| |
|
| overrides this switch regardless of position. |
| |
5
Spare
6
Acceleration, MSB (Sets acceleration rate for wire drive) see below
7
Acceleration | (Sets acceleration rate for wire drive) see below |
8
Acceleration, LSB (Sets acceleration rate for wire drive) see below
Note: the factory shipped settings for all of the S1 and S2 switches is “OFF”.
MSB - Most Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the left. LSB - Least Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the right.
POWER FEED 10