Lincoln Electric IM584-D manual Wire Reel Loading READI-REELS, Spools or Coils, Electrode Polarity

Page 29

B-7

OPERATION

B-7

 

 

 

WIRE DRIVE -- PC BOARD ADJUSTMENTS

ELECTRODE POLARITY:

The system needs to be aware of the electrode polari- ty. A DIP switch setting on the Wire Drive PC board is used for this purpose. See INSTALLATION Section “Setting DIP Switches in the Wire Drive”.

GEAR BOX RATIO:

The systems needs to know which gear has been installed on the Wire Drive, low or high speed. A DIP switch setting on the Wire Drive PC board is used for this purpose. See INSTALLATION section “Wire Drive Ratio” for information on how to set the DIP Switch.

WIRE REEL LOADING - READI-REELS, SPOOLS OR COILS

To Mount a 30 Lb. (14 kg) Readi-Reel Package (Using the Molded Plastic K363-P Readi-Reel Adapter:)

The Spindle should be located in the LOWER mounting hole.

1)Depress the Release Bar on the Retaining Collar and remove it from the spindle. See Figure B.1.

2)Place the Adapter on the spindle.

3)Re-install the Retaining Collar. Make sure that the Release Bar “pops up” and that the collar retainers fully engage the retaining groove on the spindle.

4)Rotate the spindle and adapter so the retaining spring is at the 12 o'clock position.

5)Position the Readi-Reel so that it will rotate in a direction when feeding so as to be de-reeled from bottom of the coil.

6)Set one of the Readi-Reel inside cage wires on the slot in the retaining spring tab.

7)Lower the Readi-Reel to depress the retaining spring and align the other inside cage wires with the grooves in the molded adapter.

8)Slide cage all the way onto the adapter until the retaining spring "pops up" fully.

CAUTION

Check to be sure the Retaining Spring has fully returned to the locking position and has SECURELY locked the Readi-Reel Cage in place. Retaining Spring must rest on the cage, not the welding elec- trode.

___________________________________________

9)To remove Readi-Reel from Adapter, depress retaining spring tab with thumb while pulling the Readi-Reel cage from the molded adapter with both hands. Do not remove adapter from spindle.

POWER FEED 10

Image 29
Contents OPERATOR’S Manual California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents P306 Series Section ESection F Installation Boom Mounting of Wire Drive Unit Safety PrecautionsMounting the Wire Drive Unit Control Cable Mounting on Power SourceMounting the Control BOX Boom or Separated Bench Models Control Cable ConnectionsElectrode Cable Connections Control Cable SpecificationsAvailable Cable Assemblies Changing the Wire Drive Ratio Wire Drive Gear Ratio High or LOW SpeedWork Cable Connections Selecting the Proper Gear RatioRatio Change Procedure Setting DIP Switches in the Control BOX DIP Switch Setup8INSTALLATIONA-8 LSB Figure A.4 Setting DIP Switches in the Wire DriveProcedure to Install Drive Rolls and Wire Guides Wire Feed Drive Roll KitsGUN and Cable Assemblies with Standard Connection GUN and Cable Assemblies with FAST-MATECONNECTIONGUN Connections General General GUN Connection GuidelinesWire Feed Shut Down Circuit Optional Wire Spindle PlacementGmaw Shielding GAS Water Connections for Water Cooled GunsOptional Panels for Control BOX General Panel Installation GuidelinesBoom and Bench Conversions Product Description OperationRecommended Processes and Equipment Duty CycleK1542-9 Dual Procedure / Memory Panel K1542-5 Dual Procedure PanelCV/Gouge PanelStd Control BOX Panels -- ʻLARGEʼ Option PanelsK1542-6 M Panel K1542-11 MX2 PanelK1542-12 MSP2 Panel Control BOX Panels -- SET UP Controls DescriptionControl BOX -- PC Board Adjustments Control BOX -- Using Operating LimitsOperation with Previous Software Version Wire Drive OperationWire Drive Settings -- External Gear BOX Ratio Wire Reel Loading READI-REELS, Spools or CoilsElectrode Polarity Figure B.1 Drive Roll Pressure Setting Feeding Electrode and Brake AdjustmentProcedure for Setting Angle of Feedplate GAS Guard Regulator SettingMaking a Weld Wire Reel ChangingWire Feed Overload Protection Status Light States Component Status LightsStatus Light States CONʼT Wire Size Solid Steel Electrode AccessoriesCored Electrode Aluminum ElectrodeK1542-5 Dual Procedure Panel Description and Installation of Optional Control BOX PanelsConstant Voltage CV/Weld, CV/MIG, CV/Flux Cored Procedures CC/STICK/GOUGE ModeK1542-11 MX2 Panel Large Panel 10 MS/STT Panel Large Panel K1542-9 Dual Procedure Memory Panel Small Panel K1543, K1544 and K1545 Input Cable Assemblies K1548-1 Linc NET Receptacle KIT Input and Output Control Box Cabinet ProcedureFeeder Head Enclosure Procedure K1504-1 Coil Adapter K162H Wire Spindle AdapterK435 Coil Adapter K363P READI-REEL AdapterGUN Receiver Bushings and Adapters Guns and GUN AdaptersConduit Adapters Dual Procedure Switch OptionsUsing Dual Procedure with FAST-MATE Guns K1536-1 Water Flow Sensor KIT K590-5 Water Connection KIT for Drive onlyK659-1 GAS Guard Regulator K1557-1 Swivel MountMaintenance MaintenanceWire Drive Motor and Gearbox Gun and Cable MaintenanceHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Troubleshooting Your local Lincoln Authorized Possible Cause Recommended Symptoms Course of ActionField Service Facility Troubleshooting Course of Action Possible CauseEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Switch 8 must be set to 1 or ON. Field Service Facility Err 003 Err 001Err 004 Err 005Err 100 Err 020Err 200 Err 201Err 212 Err 211Diagrams Wiring Diagram Power Feed 10 Wire Drive Diagrams2000 L10599 Power FeedPower Feed Power Feed Power Feed Precaucion Warnung