Lincoln Electric IM584-D manual Wire Feed Drive Roll Kits, Electric Shock can kill

Page 19

A-11

INSTALLATION

A-11

 

 

 

WIRE FEED DRIVE ROLL KITS

NOTE: The maximum rated solid and cored wire sizes and selected drive ratios are shown on the SPECIFICATIONS in the front of this sec- tion.

The electrode sizes that can be fed with each roll and guide tube are stenciled on each part. Check the kit for proper components. Kit specifications can be found in the ACCESSORIES section.

PROCEDURE TO INSTALL DRIVE ROLLS AND WIRE GUIDES

WARNING

ELECTRIC SHOCK can kill.

Do not touch electrically live parts such as output terminals or internal wiring.

When feeding without Power Feed 10 “Cold Feed” feature, electrode and drive mechanism are “hot” to work and ground and could remain energized several seconds after the gun trigger is released.

Turn OFF input power at welding power source before installation or changing drive roll and/or guide tubes.

Welding power source must be connected to system ground per the National Electrical Code or any applicable local codes.

Only qualified personnel should perform this installation.

Observe all additional Safety Guidelines detailed throughout this manual.

Drive Roll Kit Installation (KP1505-[ ])

1)Turn OFF Welding Power Source.

2)Pull open Pressure Door to expose rolls and wire guides.

3)Remove Outer Wire Guide by turning knurled thumb screws counter-clock-wise to unscrew them from Feedplate.

4)Remove drive rolls, if any are installed, by pulling straight off shaft. Remove inner guide.

5)Insert inner Wire Guide, groove side out, over the two locating pins in the feedplate.

6)Install each drive roll by pushing over shaft until it butts up against locating shoulder on the drive roll

shaft. (Do Not exceed maximum wire size rating of the wire drive).

7)Install Outer Wire Guide by sliding over locating pins and tightening in place.

8)Engage upper drive rolls if they are in the “open” position and close Pressure Door.

TO SET DRIVE ROLL PRESSURE, see “Drive Roll Pressure Setting” in OPERATION.

GUN AND CABLE ASSEMBLIES WITH STANDARD CONNECTION

The Power Feed 10 wire feeder is equipped with a factory installed K1500-2 gun connection Kit. This kit is for guns having a Tweco™ #2-#4 connector. The Power Feed 10 has been designed to make connect- ing a variety of guns easy and inexpensive with the K1500 series of gun connection kits. Gun trigger and dual procedure lead connections connect to the single 5 pin receptacle on the front of the feed head box. See “Gun Adapters” in ACCESSORIES section.

GUN AND CABLE ASSEMBLIES WITH FAST-MATECONNECTION

(including the Magnum 450 Water Cooled gun)

A K489-7 adapter will install directly into the wire drive feedplate, to provide for use of guns with Fast-Mate™ or European style gun connections. This K489-7 will handle both standard Fast-Mate™and Dual Schedule Fast-Mate™ guns.

Another way to connect a gun with a Fast-Mate™ or European style gun connector to the Power Feed 10, is to use the K489-2 Fast-Mate™ adapter kit. Installation of this adapter also requires a K1500-1 gun connector. See “Gun Adapters” in ACCES- SORIES section.

POWER FEED 10

Image 19
Contents OPERATOR’S Manual California Proposition 65 Warnings SafetyElectric Shock can kill Iii Welding and Cutting Sparks can Cause fire or explosionSûreté Pour Soudage a LʼArc Précautions DE SûretéThank You Table of Contents Section F Section EP306 Series Installation Mounting the Wire Drive Unit Safety PrecautionsBoom Mounting of Wire Drive Unit Control Cable Connections Mounting on Power SourceControl Cable Mounting the Control BOX Boom or Separated Bench ModelsAvailable Cable Assemblies Control Cable SpecificationsElectrode Cable Connections Selecting the Proper Gear Ratio Wire Drive Gear Ratio High or LOW SpeedChanging the Wire Drive Ratio Work Cable ConnectionsRatio Change Procedure Setting DIP Switches in the Control BOX DIP Switch Setup8INSTALLATIONA-8 LSB Figure A.4 Setting DIP Switches in the Wire DriveGUN and Cable Assemblies with FAST-MATECONNECTION Wire Feed Drive Roll KitsProcedure to Install Drive Rolls and Wire Guides GUN and Cable Assemblies with Standard ConnectionGUN Connections General General GUN Connection GuidelinesWater Connections for Water Cooled Guns Wire Spindle PlacementWire Feed Shut Down Circuit Optional Gmaw Shielding GASBoom and Bench Conversions General Panel Installation GuidelinesOptional Panels for Control BOX Duty Cycle OperationProduct Description Recommended Processes and EquipmentK1542-9 Dual Procedure / Memory Panel K1542-5 Dual Procedure PanelK1542-11 MX2 Panel Control BOX Panels -- ʻLARGEʼ Option PanelsCV/Gouge PanelStd K1542-6 M PanelK1542-12 MSP2 Panel Control BOX Panels -- SET UP Controls DescriptionControl BOX -- PC Board Adjustments Control BOX -- Using Operating LimitsWire Drive Settings -- External Wire Drive OperationOperation with Previous Software Version Electrode Polarity Wire Reel Loading READI-REELS, Spools or CoilsGear BOX Ratio Figure B.1 GAS Guard Regulator Setting Feeding Electrode and Brake AdjustmentDrive Roll Pressure Setting Procedure for Setting Angle of FeedplateWire Feed Overload Protection Wire Reel ChangingMaking a Weld Status Light States Component Status LightsStatus Light States CONʼT Aluminum Electrode AccessoriesWire Size Solid Steel Electrode Cored ElectrodeK1542-5 Dual Procedure Panel Description and Installation of Optional Control BOX PanelsConstant Voltage CV/Weld, CV/MIG, CV/Flux Cored Procedures CC/STICK/GOUGE ModeK1542-11 MX2 Panel Large Panel 10 MS/STT Panel Large Panel K1542-9 Dual Procedure Memory Panel Small Panel K1543, K1544 and K1545 Input Cable Assemblies Feeder Head Enclosure Procedure Control Box Cabinet ProcedureK1548-1 Linc NET Receptacle KIT Input and Output K363P READI-REEL Adapter K162H Wire Spindle AdapterK1504-1 Coil Adapter K435 Coil AdapterGUN Receiver Bushings and Adapters Guns and GUN AdaptersUsing Dual Procedure with FAST-MATE Guns Dual Procedure Switch OptionsConduit Adapters K1557-1 Swivel Mount K590-5 Water Connection KIT for Drive onlyK1536-1 Water Flow Sensor KIT K659-1 GAS Guard RegulatorGun and Cable Maintenance MaintenanceMaintenance Wire Drive Motor and GearboxHOW to USE Troubleshooting Guide 1TROUBLESHOOTINGE-1Troubleshooting Field Service Facility Possible Cause Recommended Symptoms Course of ActionYour local Lincoln Authorized Troubleshooting Course of Action Possible CauseEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Switch 8 must be set to 1 or ON. Field Service Facility Err 005 Err 001Err 003 Err 004Err 201 Err 020Err 100 Err 200Err 212 Err 211Diagrams Wiring Diagram Power Feed 10 Wire Drive Diagrams2000 L10599 Power FeedPower Feed Power Feed Power Feed Precaucion Warnung