Lincoln Electric IM584-D manual Guns and GUN Adapters, GUN Receiver Bushings and Adapters

Page 44

C-10

ACCESSORIES

C-10

 

 

 

GUNS AND GUN ADAPTERS

The Power Feed 10 wire feeder is equipped with a factory installed K1500-2 gun connection Kit. This kit is for guns having a Tweco™ #2-#4 connector. The Power Feed 10 has been designed to make connect- ing a variety of guns easy and inexpensive with the K1500 series of gun connection kits. Gun trigger and dual procedure lead connections connect to the single 5 pin receptacle on the front of the wire drive box.

MAGNUM 200/300/400 GUNS

The easiest and least expensive way to use Magnum 200/300/400 guns with the Power Feed 10 wire feeder is to order them with the K466-10 connector kit, or to buy a completely assembled Magnum gun having the K466-10 connector (such as the K471-21, -22, and - 23 dedicated Magnum 400 guns and the K497-20 and -21 dedicated Magnum 200 guns).

MAGNUM 550 GUNS

The easiest and least expensive way to use the Magnum 550 guns with Power Feed 10 wire feeders is to order the gun with the K613-2 connector kit, and install a K1500-3 gun connection kit to the wire feeder.

LINCOLN INNERSHIELD AND SUB ARC GUNS

All of these guns can be connected to the Power Feed by using the K1500-1 Adapter Kit.

LINCOLN FUME EXTRACTION GUNS

The K556 (250XA) and K566 (400XA) guns require that a K489-7 Fast-Mate™ adapter kit be installed.

The K206, K289, and K309 require only the installa- tion of a K1500-1 connector in the Power Feed wire feeder.

NON-LINCOLN GUNS

Most competitive guns can be connected to the Power Feed by using one of the K1500 series adapter kits.

GUN RECEIVER BUSHINGS AND ADAPTERS

K489-7 (DUAL SCHEDULE FAST-MATE ADAPTER)

This adapter installs directly into the wire drive feed- plate, to provide for use of guns with Fast-Mate or European style gun connections. This K489-7 will handle both standard Fast-Mate and Dual Schedule Fast-Mate guns.

K1500-1 (LINCOLN INNERSHIELD GUN STANDARD CONNECTION)

Use this kit to connect the following guns: Guns hav- ing a Lincoln standard Innershield gun connector, Magnum 200/300/400 with K466-1 connector kit, and Magnum 550 guns with the K613-1 gun connection kit.

K1500-2 (TWECO #2-#4 TYPE CONNEC- TION)

The K1500-2 gun adapter comes factory installed on the Power Feed 10 wire feeder. Use this adapter for guns that have a Tweco #2-#4 connector. Such guns include Magnum 200/300/400 guns with K466-2 con- nector kit, and completely factory assembled Magnum guns that are factory equipped with the K466-2 con- nector (such as the K471-21, -22, and -23 dedicated Magnum 400 guns and the K497-20 and -21 Magnum 200 guns).

K1500-3 (TWECO #5 CONNECTION)

For Magnum 550 gun with K613-2 Connection Kit, and any other gun having a Tweco #5 connector .

K1500-4 (MILLER CONNECTION)

For any gun having a newer style Miller connector. Install gun adapters per the instructions shipped with it.

POWER FEED 10

Image 44
Contents OPERATOR’S Manual Safety California Proposition 65 WarningsElectric Shock can kill Welding and Cutting Sparks can Cause fire or explosion IiiPrécautions DE Sûreté Sûreté Pour Soudage a LʼArcThank You Table of Contents P306 Series Section ESection F Installation Boom Mounting of Wire Drive Unit Safety PrecautionsMounting the Wire Drive Unit Mounting on Power Source Control CableMounting the Control BOX Boom or Separated Bench Models Control Cable ConnectionsElectrode Cable Connections Control Cable SpecificationsAvailable Cable Assemblies Wire Drive Gear Ratio High or LOW Speed Changing the Wire Drive RatioWork Cable Connections Selecting the Proper Gear RatioRatio Change Procedure DIP Switch Setup Setting DIP Switches in the Control BOX8INSTALLATIONA-8 LSB Setting DIP Switches in the Wire Drive Figure A.4Wire Feed Drive Roll Kits Procedure to Install Drive Rolls and Wire GuidesGUN and Cable Assemblies with Standard Connection GUN and Cable Assemblies with FAST-MATECONNECTIONGeneral GUN Connection Guidelines GUN Connections GeneralWire Spindle Placement Wire Feed Shut Down Circuit OptionalGmaw Shielding GAS Water Connections for Water Cooled GunsOptional Panels for Control BOX General Panel Installation GuidelinesBoom and Bench Conversions Operation Product DescriptionRecommended Processes and Equipment Duty CycleK1542-5 Dual Procedure Panel K1542-9 Dual Procedure / Memory PanelControl BOX Panels -- ʻLARGEʼ Option Panels CV/Gouge PanelStdK1542-6 M Panel K1542-11 MX2 PanelControl BOX Panels -- SET UP Controls Description K1542-12 MSP2 PanelControl BOX -- Using Operating Limits Control BOX -- PC Board AdjustmentsOperation with Previous Software Version Wire Drive OperationWire Drive Settings -- External Gear BOX Ratio Wire Reel Loading READI-REELS, Spools or CoilsElectrode Polarity Figure B.1 Feeding Electrode and Brake Adjustment Drive Roll Pressure SettingProcedure for Setting Angle of Feedplate GAS Guard Regulator SettingMaking a Weld Wire Reel ChangingWire Feed Overload Protection Component Status Lights Status Light StatesStatus Light States CONʼT Accessories Wire Size Solid Steel ElectrodeCored Electrode Aluminum ElectrodeDescription and Installation of Optional Control BOX Panels K1542-5 Dual Procedure PanelCC/STICK/GOUGE Mode Constant Voltage CV/Weld, CV/MIG, CV/Flux Cored ProceduresK1542-11 MX2 Panel Large Panel 10 MS/STT Panel Large Panel K1542-9 Dual Procedure Memory Panel Small Panel K1543, K1544 and K1545 Input Cable Assemblies K1548-1 Linc NET Receptacle KIT Input and Output Control Box Cabinet ProcedureFeeder Head Enclosure Procedure K162H Wire Spindle Adapter K1504-1 Coil AdapterK435 Coil Adapter K363P READI-REEL AdapterGuns and GUN Adapters GUN Receiver Bushings and AdaptersConduit Adapters Dual Procedure Switch OptionsUsing Dual Procedure with FAST-MATE Guns K590-5 Water Connection KIT for Drive only K1536-1 Water Flow Sensor KITK659-1 GAS Guard Regulator K1557-1 Swivel MountMaintenance MaintenanceWire Drive Motor and Gearbox Gun and Cable Maintenance1TROUBLESHOOTINGE-1 HOW to USE Troubleshooting GuideTroubleshooting Your local Lincoln Authorized Possible Cause Recommended Symptoms Course of ActionField Service Facility Troubleshooting Possible Cause Course of ActionEither of these fail, the problem is Change Or harness disconnected from Fails the continuity test, repair or Switch 8 must be set to 1 or ON. Field Service Facility Err 001 Err 003Err 004 Err 005Err 020 Err 100Err 200 Err 201Err 211 Err 212Diagrams Diagrams Wiring Diagram Power Feed 10 Wire DrivePower Feed 2000 L10599Power Feed Power Feed Power Feed Precaucion Warnung