ADJUSTING THE NAILING DEPTH
To assure that each nail penetrates to the same depth, be sure that:
1)the air pressure to the Nailer remains constant (requlator is installed and working properly), and
2)the Nailer is always held firmly against the workpiece. If nails are driven too deep or shallow into the workpiece, adjust the nailing in the following order.
1 DISCONNECT AIR HOSE FROM NAILER
Adjuster
15
Disconnect air hose
2If nails are driven too deep, turn the adjuster to the shallow side.
Adjustments are in
2Turn Adjuster
Too Deep | Flush |
If nails are driven too shallow, turn the adjuster to the deep side.
2 | Turn Adjuster |
Too Shallow | Flush |
|
3Stop turning the adjuster when a suitable position is reached for a nailing test.
4Connect the air hose.
ALWAYS WEAR EYE PROTECTOR.
Perform a nailing test.
5DISCONNECT AIR HOSE FROM NAILER.
6 Choose a suitable position for the adjuster.
CHANGING THE EXHAUST DIRECTION
The direction of the exhaust vent can be changed by turning the top cover.
Top Cover
Exhaust
Vent
USING THE NOSE CAP
If you like to protect the surface of workpiece against scratches or markings made by the push lever, attach the accessory nose cap to the push lever.
1DISCONNECT AIR HOSE FROM NAILER.
2Put the nose cap to the toe of the push lever.
NOTE:
The nose cap may reduce nailing depth due to its thickness.
Push Lever
1
2 | Do not connect | |
air hose | ||
| ||
Nose Cap |
|
— 14 —