State Industries SUF-60-120, SUF-100-250 instruction manual Back Advanced, View Back Help, Eco, Yes

Page 50

Current Fault

Description/Action

 

 

Display

 

 

 

Select Current Fault from the Main Menu and press the

 

 

 

 

 

 

Operational Button under "SELECT" to enter this menu. This

 

 

 

 

 

 

menu contains non adjustable operational information. Use the

 

 

Blocked Exhaust

 

Up & Down Buttons to navigate the menu.

 

 

 

This menu contains the current Fault or Alert error message.

 

 

Fault occurred 2 mins ago

 

 

 

 

The exhaust is blocked or

 

 

 

The time the Fault or Alert message occurred appears directly

 

 

 

 

 

restricted. Ensure

 

 

 

 

 

 

 

below. A brief description of what causes the particular Fault or

 

 

 

 

 

condensate hose is draining.

 

 

Alert condition appears below that. Pressing the Operational

 

 

 

 

 

 

 

 

 

Button under "ADVANCED" will give more detailed service

 

Call a service professional:

 

 

information and a list of possible causes for the Fault or Alert

 

 

 

 

Your Company Name Here

 

 

condition. See Fault And Alert Messages on page 62 for more

 

 

 

 

(press [DOWN] for more....)

 

 

 

 

 

detailed information and diagnostic procedures.

 

 

 

 

 

 

 

CHANGE

BACK

ADVANCED

 

If there is no Fault or Alert condition active this menu will not

 

 

 

 

 

 

 

 

contain any information, "(none)" will be shown next to Current

 

 

 

 

 

 

Fault in the Main menu.

 

 

 

 

 

 

Fault History

 

 

 

 

 

 

Description/Action

 

Display

 

Select Fault History from the Main Menu and press the

 

Fault History

 

Operational Button under "SELECT" to enter this menu. This

 

 

1:

Blocked Air Intake (A7)

menu contains non adjustable operational information. Use the

Up & Down Buttons to navigate the menu.

 

 

51 mins ago

This menu contains a list of the last nine (9) Fault and Alert

2:

Blocked Exhaust (A8)

messages with a time stamp. The newest event will replace the

 

 

54 mins ago

oldest.

3:

Low Gas Pressure (A6)

Press the Operational Button under "VIEW" to view details for

 

 

57 mins ago

each Fault or Alert message stored.

4:

Blower Prover Failure (AC)

 

VIEW

BACK

HELP

Fault Occurrence

 

 

 

Description/Action

 

Display

 

Select Fault Occurrence from the Main Menu and press the

Fault Occurrence

Operational Button under "SELECT" to enter this menu. This

Ignition Failure

 

10

menu contains non adjustable operational information. Use the

 

Up & Down Buttons to navigate the menu.

ECO

 

0

This menu contains a running total of how many times each

Low Gas Pressure

10

Fault condition has occurred since the water heater was first

Blocked Intake Air

0

installed.

Blocked Exhaust

0

Note: Historical data is stored in the CCB's memory. If this

Thermostat Input 4

0

CCB is replaced during servicing the historical data on the CCB

Blower Prover

 

3

being replaced will be lost. The data stored in the new circuit

 

BACK

HELP

board will no longer reflect the entire history of the water heater.

 

Restore Factory Defaults

 

 

 

Description/Action

 

Display

 

Select Restore Factory Defaults from the Main Menu and press

Restore Factory Defaults

the Operational Button under "SELECT" to enter this menu.

To restore the adjustable user settings to their factory default

 

Are you sure you want to

settings press the Operational Button underneath “YES.” The

 

display will show text confirming the factory default settings

 

restore the system to factory

have been restored.

 

defaults?

Press the Operational Button underneath “BACK” to exit the

 

 

Restore Factory Defaults menu.

 

 

 

YES

NO

50

Image 50
Contents Commercial gas water heaters Table Of Contents Safe Installation, Use and Service ApprovalsHydrogen Gas Flammable General Safety InformationPrecautions Overheated water can cause water tank explosionFire and Explosion Hazard Installing, using or servicing Water heaterFire or Explosion Hazard Abbreviations Used Preparing For The InstallationIntroduction QualificationsFeatures And Components Basic OperationSUF 120 & 150 Components Water Heater’s 120 VAC on/off switchTop Views 120,000 & 150,000 Water heaters 24 Volt Gas Valve Top ViewsSUF 199 & 250 Components Left Side Right Side TOP Views Installation ConsiderationsRough In Dimensions Gas Line Connection Size Recovery CapacitiesLocating The Water Heater Storage CapacitiesHard Water Extended Vent TerminationsOptional Concentric Terminations Circulation PumpsGas Pressure Requirements Installation RequirementsPower Supply Supply Gas LineClosed Water Systems Mixing ValvesDishwashing Machines Thermal ExpansionValve Discharge Pipe Requirements Temperature-Pressure Relief ValveWater Damage Hazard Contaminated Air Condensate DrainCombustible Material Storage Condensate Drain Water TrapUnconfined Space Breathing Hazard Carbon Monoxide GasAir Requirements Confined SpaceOutdoor Air Through One Opening Fresh Air Openings For Confined SpacesOutdoor Air Through Two Openings Outdoor Air Through Two Horizontal DuctsPage Commonwealth of Massachusetts InspectionGeneral Venting Instructions Venting InstallationGeneral Venting Information Large Hose Fernco Clamp SUF 199 & SUF 250 Intake Air ConnectionCorrect Orientation TEE FittingVenting Requirements Direct Vent Installation Venting Installation SequencePower Vent Installation Intake AIR Screen Field SuppliedVertical Termination Installation Standard Factory Supplied TerminationsIntake AIR AND/OR Vent Exhaust Maximum Factory Supplied Standard TerminationField Supplied STRAP/SUPPORT Sidewall Termination Installation Concentric Termination Installation Determine the location for the terminationInch Concentric Termination Installation Inch Concentric Termination KITFour Concentric Terminations TWO Concentric TerminationsThree Concentric Terminations Eight Concentric TerminationsEight Concentric Terminations Multiple Concentric Termination ArrangementsTwo Concentric Terminations Sidewall RoofDirect Vent Horizontal Power Vent HorizontalVenting Arrangements Direct Vent Horizontal Concentric Direct Vent Vertical Vent Horizontal IntakeDirect Vent Horizontal Vent Vertical Intake Termination Clearances Sidewall Power Vent Power VentTermination Clearances Sidewall Direct Vent Direct VentInstallation Notes Water Heater InstallationCondensate Drain Installation Installation InstructionsSupply Gas Line Sizing U. S. Units Supply Gas Line InstallationGas Line Sizing Supply Gas Line Sizing Metric UnitsGas Line Connection Supply Gas Regulator InstallationGas Line Leak Testing Enable/Disable Circuit Electrical WiringPower Supply Connections Connecting An External Supervisory ControlValve Discharge Pipe Water Piping DiagramsWater Line Connections Thermometers not SuppliedHigh Temperature Applications Temperature RegulationHigh Temperature Limit Control ECO Thermostat ControlOverview Tank Temperature 103F Operating Set Point 120FControl System Operation Control System NavigationStatus Icons Icon DescriptionControl System Menus Operating StatesState Description Menu DescriptionBack Help User Settings & Control System MenusUpdate Cancel Description/Action DisplayChange Back Help Display Settings Description/Action Heater Information Description/Action DisplayECO Back AdvancedView Back Help YESSelect Back Help UpdateService Contact Information NameInitial Start Up Start UpPrior to Start up Lighting The Water Heater GAS Valve / Venturi Assembly TOP ViewGAS Valve TOP Detail View Gas pressure reading while the water heater is firingMultiple Appliance Installations 1050 = 300,000 Btu/hr 87.9 kW High Altitude InstallationsChecking The Firing Rate To Turn Off GasLighting & Operation Labels Lighting The Water HeaterSUF 60 120 and SUF 100 150 Models only Tank Temperature 103F Operating Set Point 120F SUF 100 199 and SUF 100 250 Models onlySequence Of Operation TroubleshootingInstallation Checklist Pre-Purge cycle Sequence Of Operation Flow ChartClosed by control system Fault Msg is displayed Rough Starting, Rough Operation Operational ProblemsInstallation Errors Momentary IgnitionFault And Alert Conditions Back Advanced Fault And Alert MessagesPossible Causes Check/Repair Displayed Fault/Alert Message Blower Prover Failure No Anode VoltageGeneral MaintenanceMaintenance Schedule Draining And FlushingLime Scale Removal Filling The Water HeaterSediment Removal Manual Lime Scale RemovalTemperature-Pressure Relief Valve Test Powered Anode RodsDrain Valve and Access Panels Vent SystemJ10 J13 J11 DiagramsJ3 J5 CCB Central Control Board LayoutSUF 120 & 150 Wiring Diagram User Interface ModulSUF 199 & 250 Wiring Diagram CCB Central Control BoardCirculation Pump Wiring Diagrams Water Piping Diagrams Temperature & Pressure Tank Temperature ALT. Cold Water State Storage Tank Water Piping Diagrams Line Temperature Control HOT Water Outlet Pipe T&P to Open Drain Finished Floor Limited Warranty