Vulcan-Hart SG6C ML-114878 Installation Codes And Standards, In the United States of America

Page 6
INSTALLATION CODES AND STANDARDS

INSTALLATION CODES AND STANDARDS

Vulcan ovens must be installed in accordance with:

In the United States of America:

1.State and local codes.

2.National Fuel Gas Code, ANSI-Z223.1 (latest edition). Copies may be obtained from The American Gas Association, Inc., 1515 Wilson Blvd., Arlington, VA 22209.

3.National Electrical Code, ANSI/NFPA-70 (latest edition). Copies may be obtained from The National Fire Protection Association, Batterymarch Park, Quincy, MA 02269.

In Canada:

1.Local codes.

2.CSA B149.1 Natural Gas and Propane Installation Code.

3.CSA C22.1 Canadian Electrical Code.

The above are available from the Canadian Standard Association, 5060 Spectrum Way, Suite 100, Mississauga, Ontario, Canada L4W 5N6.

INSTALLING BASIC OVEN

The basic oven must be installed on legs, casters or mounted on a modular stand. Installations on concrete bases or other supports restricting air circulation underneath the oven is not advisable and may void the warranty.

Ovens Mounted on Casters

Ovens mounted on casters must use a flexible connector (not supplied by Vulcan) that complies with the Standard for Connectors for Movable Gas Appliances, ANSI Z21.69 • CSA 6.16 and a quick-disconnect device that complies with the Standard for Quick-Disconnect Devices for Use With Gas Fuel, ANSI-Z21.41 • CSA 6.9. In addition, adequate means must be provided to limit movement of the appliance without depending on the connector and the quick-disconnect device or its associated piping to limit appliance movement. Attach the restraining device at the rear of the oven as shown in Fig. 1.

If disconnection of the restraint is necessary, turn off the gas supply before disconnection. Reconnect this restraint prior to turning the gas supply on and returning the oven to its installation position.

Separate instructions for installing casters to the oven are included with the casters.

CONNECT GAS LINE STRAIN RELIEF HERE

Fig. 1

PL-52805

Note: If the oven is installed on casters and is moved for any reason, it is recommended that the oven be releveled front to back and side to side for even baking.

— 6 —

Image 6
Contents SG SERIES GAS SNORKEL CONVECTION OVENS IMPORTANT FOR YOUR SAFETY FOR YOUR SAFETYTABLE OF CONTENTS GAS SNORKEL CONVECTION OVENS Installation, Operation and Care ofMODEL SG4D, SG4C, SG6D & SG6C PLEASE KEEP THIS MANUAL FOR FUTURE USE GENERALINSTALLATION UNPACKINGLOCATION In the United States of America INSTALLATION CODES AND STANDARDSINSTALLING BASIC OVEN In CanadaBACK FRONT Assembling the Legs to the OvenAssembling the Stand to the Oven ASSEMBLING STACKED OVENS LEVELING ELECTRICAL CONNECTIONSGAS AND ELECTRICAL DATA TESTING THE GAS SUPPLY SYSTEM ADJUSTMENTS Air AdjustmentGAS CONNECTIONS VENT SYSTEM OPERATION CONTROLS - MODELS SG4D AND SG6D FigDial Setting Master SwitchPower Level Control One-HourTimerUSING THE SG4D AND SG6D OVENS Preheating LIGHTING THE SG4D AND SG6D OVENSCooking End of Day Extended ShutdownMENU SELECT 3/4To Set the Cook Time To Set the Power LevelTo Change the Time Setting for any Menu Item To Set the TemperatureTo Display the Actual Oven Temperature SETTING THE OVEN FOR ROAST & HOLDStarting a Timed Cycle On All Racks To End a Cooking Cycle300ºF ROAST AND HOLD OPERATIONROAST AND HOLD DIAGRAM - Time vs. Temperature 200ºFArrangement #2 RACK ARRANGEMENTSArrangement #1 Arrangement #3CONSERVING ENERGY COOKING GUIDELINESROASTING TEMPERATURE CHART Page Contd REHEATING PREPARED FOODSOVEN BROILING OR FRYING CASSEROLESMISCELLANEOUS PRODUCTS NOTES ON SPECIAL PROCEDURES FOR BAKING HIGH LIMIT SWITCHCLEANING Snorkel TubeDaily LUBRICATION MAINTENANCESERVICE AND PARTS INFORMATION VENTCAUSE TROUBLESHOOTING GUIDEPROBLEM CORRECTIONCAUSE DÉPANNAGECORRECTIF PROBLÈMEENTRETIEN RECHANGE DE PIÈCES ET L’ENTRETIEN DE SERVICEAVERTISSEMENT quotidien NettoyageSnorkel Tube NETTOYAGEDIVERS ALIMENTS CASSEROLESFOUR AU GRILLAGE ET FRITURE CUISINÉS PLATS DE RÉCHAUFFAGE Page RÔTISSAGE DE TEMPÉRATURES D’UTILISATION CONSEILSL’ÉNERGIE DE CONSERVATION 2 n Arrangement 4 n Arrangement3 n Arrangement 1 n ArrangementCHAUD-AU-GARDEET RÔTISSAGE MODE Page température la régler Pour cuisson la commencer Pourpuissance de niveau le régler Pour cuisson de temps le régler PourPage Page prolongé Arrêt SG6D ET SG4D FOURS DES UTILISATION 10 à puissance de commutateur le RéglerCuisson SG6D ET SG4D FOURS DES ALLUMAGEPuissance UTILISATION PREMIÈRE UNE AVANTvitesses deux à RéglageFONCTIONNEMENT 4 .Fig SG6D ET SG4D MODÈLES DES COMMANDESD’ÉVACUATION SYSTÈME GAZ DE CANALISATION LA DE ESSAIS GAZ DU BRANCHEMENTGAZ DE ET ÉLECTRIQUES CARACTÉRISTIQUES ÉLECTRIQUE RACCORDEMENTNIVELAGE FOURS DE SUPERPOSITION FOUR DU AVANT FOUR DU ARRIÈRE support le sur four du Assemblagepattes des Assemblage roulettes sur Appareils NORMES ET D’INSTALLATION CODESBASE DE FOUR DU INSTALLATION Unis-ÉtatsAuxINSTALLATION DÉBALLAGECARACTÉRISTIQUES MATIÈRES DES TABLE AVERTISSEMENT IMPORTANTES SÉCURITÉ DE MESURESAVERTISSEMENT SNORKEL D’EMPLOI MODE ET DINSTALLATION MANUELSG SÉRIE LA DE GAZ AU PULSÉ AIR À FOUR