PERFORMANCE DATA SHEET
Water Filtration System
Model P5WB2L/P4RFWB Capacity 200 Gallons (757 Liters)
@System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor, and Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Live Cysts, Asbestos, Lead, Lindane, Toxaphene, Atrazine, and 2,4 - D.
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The
concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the
permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance | Reduction | NSF Reduction | Average | Influent | Challenge | Maximum |
| Minimum | % | Average | % | |||||
Aesthetic | Effects | Requirements | Influent | Concentration | Effluent |
| Reduction |
| Reduction | |||||||
Chlorine Taste/Odor | 50% | reduction | 2.0 mg/L | 2.0 mg/L + 10% | 0.20 mg/L | ** | 97 |
| 97.2 |
| ||||||
99 |
|
| ||||||||||||||
Particulate | Class I* | 85% | reduction | 7,300,000 #/mL | At least | 10,000 particles/mL | 75,000 | #/mL |
|
| 99.4 |
| ||||
| Minimum | % |
| |||||||||||||
Contaminant | NSF Reduction | Average | Influent | Challenge | Maximum |
| Average | % | ||||||||
| Reduction |
| ||||||||||||||
Reduction |
| Requirements | Influent | Concentration | Effluent |
|
| Reduction |
| |||||||
|
|
|
|
| ||||||||||||
Live Cysts _ | 99.95% | 160,OOO/L | 5O,OOO/Lmin. | 54/U |
|
| 99.97 |
| 99.99 |
| ||||||
Asbestos |
| 99% |
| 87 MFL | 1OTto 1OSfibers/U _ | 0.17 MFL |
| 99 |
| 99 |
| |||||
Lead: @ pH 6.5 | 0.010 | mg/L | 0.160 | mg/L | 0.15 | mg/L | + 10% | 0.001 | mg/L |
| 99.4 |
| 99.4 |
| ||
| 98.6 |
|
| |||||||||||||
Lead: @ pH 8.5 | 0.010 | mg/L | 0.140 | mg/L | 0.15 | mg/L | _+10% | 0.005 | mg/L |
|
| 98.6 |
| |||
Lindane |
| 0.0002 mg/L | 0.0019 | mg/L | 0.002 | mg/L | _+10% | 0.00002 mg/L | 98.9 |
| 99 |
| ||||
|
|
|
| |||||||||||||
Toxaphene |
| 0.003 | mg/L | 0.014 | mg/L | 0.015 | mg/L | _+10% | 0.001 | mg/L |
| 93 |
| 93 |
| |
Atrazine |
| 0.003 | mg/L | 0.0094 | mg/L | 0.009 | mg/L | _+10% | 0.0005 | mg/L |
| 94.5 |
| 94.7 |
| |
2,4 - D |
| 0.07 | mg/L | 0.220 | mg/L | 0.210 | mg/L | _+10% | 0.028 | mg/L |
| 87.5 |
| 96.1 |
| |
|
|
|
|
|
Test Parameters: pH : 7.5 0.5 unless otherwise noted. Flow
•It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to perform as advertised.
Use replacement filter P4RFWB, part #9930.
2011 suggested retail price of $49.99 U.S.A./S59.99 Canada. Prices are subject to change without notice.
Style 1 - When the water filter status display changes from
"GOOD" to "ORDER," order a new filter. When the filter
indicator reads "REPLACE," it is recommended that you replace the filter.
•The product is for cold water use only.
•The water system must be installed in compliance with state and local laws and regulations.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be
used on disinfected waters that may contain filterable cysts.
•Refer to the "Warranty" section for the Manufacturer's name, address and telephone number.
Style 2 - When the filter indicator changes from green to yellow, order a new filter. When the indicator changes from
yellow to red, it is recommended that you replace the filter.
Style 3 - When the filter indicator reads 10%, order a new
filter. When the indicator reads 0%, it is recommended that you replace the filter.
After changing the water filter, flush the water system. See "Water and Ice Dispensers."
These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.
*Class I particle size: >0.5 to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. tBased on the use of Cryptosporidium parvum oocysts
ttFibers greater than 10 um in length
® NSF is a registered trademark of NSF International.
•Refer to the "Warranty" section for the Manufacturer's limited warranty.
Application Guidelines/Water Supply Parameters
Water | Supply | City or Well |
|
Water | Pressure | 30 - 120 psi (207 - 827 | kPa) |
Water | Temperature | 33 ° _ IO0°F (0.6 ° - 37.8°C) | |
Service | Flow Rate | 0.5 gpm (1.9 Lpm) @ 60 | psi |
%
29