Assembly
Prior to Assembly
Using Figure 3 as a guide, familiarize your- | ■ Power unit and blower assembly. | ■ Lead wire assembly |
|
self with the blower and its components. | ■ Flexible tube, swivel tube, two nozzles | Carefully inspect all components for damage. |
|
Understanding the unit helps ensure top |
| ||
and straight tube. |
|
| |
performance, longer service life, and safer |
|
| |
■ Handgrip (Non RT unit only). | IMPORTANT! |
| |
operation. | The terms “left”, |
| |
| ■ Two tube clamps (102 and 89mm). |
| |
Before assembling the blower, make sure |
| ||
you have all required components. | ■ This Owner’s/Operator’s Manual | refer to directions as viewed by the opera- |
|
| and a tool kit containing a tool | tor during normal operation. |
|
| bag, 4 mm hex wrench, 5 mm hex |
|
|
| wrench and a combination spark plug |
|
|
| wrench/screwdriver. |
|
|
Assembling the Blower
IMPORTANT!
This unit is equipped with a static dis- charge reduction wire. This wire helps direct static buildup into the air stream reducing the felt amount to the operator.
1.Place the blower upright on the ground or a sturdy work surface and note parts orientation as shown in Figure 4.
2.Remove static wire from package and fix eyelet to right hand engine cover screw. See Figure 5.
3.Turn the discharge tube out to a right angle and slip
4.Slip the flexible tube over the end of the 90° discharge tube, and secure with the 102mm clamp.
NOTE:
Swivel | Handgrip |
Tube |
|
|
| Long Nozzle |
| Flexible Tube |
| (ø74 mm) |
|
|
| |
90° Discharge Tube |
| Straight Tube |
|
|
|
| |
Wire |
|
|
|
102mm | 89mm Clamp | Swivel Tube | Short Nozzle |
Clamp |
| ||
|
| (ø65 mm) | |
Figure 4 |
|
| |
|
|
|
Check to make sure that the 90° discharge tube swivels freely. If any binding is pres- ent, loosen 102mm clamp and pull wire towards engine to get more slack and recheck for free movement.
5. | Insert the static wire through the swivel |
| tube, then install and tighten the 89mm |
| clamp over the rotating band on the |
| swivel tube. |
6. | Slide the handgrip over the swivel tube |
| and secure with the bolt and wingnut. |
7. | Fold the end of the static wire back |
| over the connection of the swivel tube. |
| See Figure 5. |
8. | Grasp the nozzle, and push the nozzle |
| over the swivel tube locking pins secur- |
Swivel
Tube
Static Wire
Fold wire
Flexible Tube
Static Wire
Connector
Figure 5
Align the lock pins with the lock slots, and push the tube and nozzle together.
Lock Pin
Lock Slot
Rotate clockwise to lock making sure the 3 lines are aligned on both tube and nozzle.
Figure 6
ing the static wire. See Figure 6. |
9. Lock the nozzle to the swivel tube by |
rotating the nozzle noting the alignment |
marks. See Figure 6. |
IMPORTANT!
Blower tube installation affects blower performance! Make sure the tubes and nozzle are correctly assembled per above, and that all connections are tight. Blower tubes may come apart during use unless tubes are aligned and locked into place.
WARNING!
Danger from rotating impeller!
Stop the engine before installing or removing the blower tubes! Never perform any maintenance or assem- bly procedures on this unit while the engine is running!