is
Legend
gburner pressure regulator
hburner pressure control cap
iburner pressure control adjusting screw
jconnector
kflat sealing plate
lsupply pressure test nipple M burner pressure test nipple
Figure 3.13 Conversion of gas control
Conversion to a different gas category
k
l
m
j
h
g i
nRemark
In the event the supply pressure for a gas category is the same as the burner pressure (see the gas tables in paragraph 3.4) then the gas control must be fitted with a flat sealing plate with cork gasket. A burner pressure that deviates in comparison to the supply pressure requires the use of a burner pressure regulator with rubber gasket. Each conversion kit contains all the necessary components.
12.If the flat sealing plate or burner pressure regulator need to be replaced:
-Unscrew the connector j from the gas control.
-If necessary, remove the flat sealing plate ! or burner pressure regulator 7.
-If necessary, fit the flat sealing plate or burner pressure regulator supplied with the conversion kit.
-Refit the connector to the gas control.
13.Refit the connector 1 of the glow igniter and ionisation rod to the controller.
14.
cNote
15.Check the burner and supply pressure (see paragraph 3.11).
16.Replace the plastic cover.
17.Remove the sticker showing the new gas category from the conversion kit, and attach it below the appliance’s rating plate. This clearly indicates that the appliance may no longer be run on the gas for which it was originally supplied.
18.Start the appliance (see paragraph 7.2).
Release R.1.3 UK | 37 |