Table 3.8 shows the wall flue terminal prescribed by A.O. Smith (installation type C13).

B

A

IMD-0075

 

Figure 3.4 Wall flue terminal

Table 3.8 Concentric wall flue terminal specifications

 

 

Specification

Description

 

 

Manufacturer

Muelink & Grol

 

 

Model

M2000 MDV SE(1)

Pipe material, flue gas discharge

Thick-walled aluminium with lip ring seal

 

 

Pipe material, air intake

Thin-walled galvanised sheet steel

 

 

Pipe diameter

Concentric

BFC 28: Ø 80/125 mm.

BFC 30, 50 and 60: Ø 100/150 mm.

1.The M2000 MDV SE model is a special version of the Mugro 3000 series. No other wall flue terminal may be used, as the BFC-appliance is approved exclusively for this model of wall flue terminal. You can order the wall flue terminal from A.O. Smith or your trade supplier, by specifying model: M2000 MDV SE.