Table 10.1 General errors (Sheet 3 of 3)

is

Symptom

Cause

Solution

Remark

 

 

 

 

Explosive ignition

Incorrect supply

Set the correct supply pressure and/or burner pressure, see

If ignition is not improved, consult your installer.

 

pressure and/or burner

’3.11 Checking the supply pressure and burner pressure’.

 

 

pressure.

 

 

 

 

 

 

 

 

Contaminated burner

Clean the burner. See ’12.4.2 Cleaning the burner’

 

 

 

 

 

 

Contaminated orifice.

Clean the orifice. See ’12.4.3 Cleaning the orifice’

 

 

 

 

 

Insufficient or no hot

Appliance is turned off.

Start-up the appliance. See ’7.2 Starting up’

 

water.

 

 

 

 

No electric power

1.

Check whether the mains switch is ON.

See appendix ’A.2 Electrical diagram BFC’.

 

 

present.

2.

Check that there is power to the mains switch.

If the error cannot be rectified, contact your installer.

 

 

 

 

 

3.

Check whether the ON/OFF switch of the ThermoControl is ON

 

 

 

 

(position I).

 

 

 

4.

Check whether there is power to the electrical connection

 

 

 

 

block.

 

 

 

5.

The voltage measured must be 230 VAC (-15%, +10%).

 

 

 

 

 

 

Hot water supply is

Reduce hot water consumption and give the appliance time to heat

If there continues to be insufficient or no hot water, consult your

 

used up.

up.

 

installer.

 

 

 

 

 

The controller is in

Put the controller in ON mode, see ’8.3 Switching into “ON mode”’.

 

 

OFF mode.

 

 

 

 

 

 

 

 

Temperature (Tset) is

Set temperature (Tset) to a higher value, see ’8.4 Setting the water

 

 

set too low.

temperature’.

 

 

 

 

 

 