is

3.9.2

IMD-0004

Figure 3.5 Roof flue terminal

Air supply and flue gas discharge

Concentric roof flue terminal

A.O. Smith Water Products Company prescribes the roof flue terminal (installation type C33) as specified in Table 3.9.

Table 3.9 Concentric roof flue terminal specifications

Specification

Description

 

 

Manufacturer

Muelink & Grol

 

 

Model

M2000 DDV SEC HR(1)

Pipe material, flue gas

Thick-walled lip ring seal

discharge

 

 

 

Pipe material, air intake

Thin-walled galvanised sheet steel

 

 

Pipe diameter

Concentric

BFC 28: 80/125 mm.

BFC 30, 50 and 60: Ø 100/150 mm.

1.The model M2000 DDV SEC HR is a special version of the Mugro 3000 series. No other roof flue terminal may be used, as the BFC- appliance is approved exclusively for this model of roof flue terminal. You can order the roof flue terminal from A.O. Smith or your trade supplier, by specifying model: M2000 DDV SEC HR.

Release R.1.3 UK

29

Page 29
Image 29
A.O. Smith 28 30 50 60 service manual Concentric roof flue terminal specifications