Warning
Maintenance may only be performed by a qualified service and maintenance engineer.
Table 10.2 Displayed errors (Sheet 1 of 10)
is
Code + Description | Possible cause | Solution | Remark | |
|
|
|
| |
S01 (blocking error) | Sensor is not | Connect the sensor lead to JP3. | See appendix ’A.2 Electrical diagram BFC’. | |
Open circuit from | (correctly) connected. |
|
| |
temperature sensor T2 |
|
|
| |
Damaged wiring or | Replace the sensor. | To replace the necessary parts, you must contact your installer. | ||
at bottom of tank. | defective sensor. |
|
| |
|
|
| ||
|
|
|
| |
S02 (blocking error) | Sensor is not | Connect the sensor lead to JP5. | See appendix ’A.2 Electrical diagram BFC’. | |
Open circuit from | (correctly) connected. |
|
| |
sensor 1 of |
|
|
| |
temperature sensor T1 |
|
|
| |
at the top of the tank(1). |
|
|
| |
Damaged wiring or | Replace sensor T1. | To replace the necessary parts, you must contact your installer. | ||
| ||||
| defective sensor. |
|
| |
|
|
|
| |
S03 (blocking error) | Sensor is not | Connect the sensor lead to JP5. | See appendix ’A.2 Electrical diagram BFC’. | |
Open circuit from | (correctly) connected. |
|
| |
sensor 2 of |
|
|
| |
Damaged wiring or | Replace sensor T1. | To replace the necessary parts, you must contact your installer. | ||
temperature sensor T1 | ||||
defective sensor. |
|
| ||
at the top of the tank(1). |
|
| ||
S04 (blocking error) | Dummy is not | Connect the dummy sensor lead(2) to JP4. | See appendix ’A.2 Electrical diagram BFC’. | |
Open circuit from | (correctly) connected. |
|
| |
dummy 1. |
|
|
| |
Defective dummy. | Replace the dummy sensor. | To replace the necessary parts, you must contact your installer. | ||
| ||||
|
|
|
| |
S05 (blocking error) | Dummy is not | Connect the dummy sensor lead(3) to JP4. | See appendix ’A.2 Electrical diagram BFC’. | |
Open circuit from | (correctly) connected. |
|
| |
dummy 2. |
|
|
| |
Defective dummy. | Replace the dummy sensor. | To replace the necessary parts, you must contact your installer. | ||
| ||||
|
|
|
| |
S11 (blocking error) | Short circuit in the | Replace sensor T2. | To replace the necessary parts, you must contact your installer. | |
Short circuit from the | sensor circuit. |
|
| |
temp. sensor T2 at the |
|
|
| |
bottom of the tank. |
|
|
| |
|
|
|
|
Release R.1.3 UK | 73 |