5

5.3Explanation of the icons

5.4ON/OFF switch of ThermoControl

INTERNAL CHECK

Figure 5.3 Internal check

5.5Navigation buttons

MENU OFF ^»ON

ÈWEEK PROGRAM EXTRA PERIOD SETTINGS

Figure 5.4 Navigation buttons

5.6PC connection.

The control panel

 

gis

 

 

 

Table 5.1 gives an explanation of the icons.

Table 5.1 Icons and their meaning

 

 

 

 

 

Icon

 

Name

Explanation

 

 

 

 

W

 

Heat demand

Heat demand detected

 

 

 

 

S

 

Purge

Pre- and post-purge using fan

 

 

 

 

D

 

Pressure switch

Pressure switch is closed

 

 

 

 

O

 

Glow

(Pre)glow

 

 

 

 

G

 

Gas control

Gas control open / ignition

 

 

 

 

V

 

Flame detection

Appliance running

 

 

 

 

The ON/OFF switch of the ThermoControl switches the appliance ON and OFF. Note that in the OFF position the appliance remains electrically live, in order for the continuous pump to stay running.

After switching on, the text INTERNAL CHECK appears on the display for about 10 seconds. The main menu then appears (see chapter ’8 Main menu’). If no selection is made in the main menu, the appliance automatically switches to OFF mode. See paragraph ’6.2 Operating modes’.

nRemark

To electrically disconnect the appliance, you must use the main switch between the appliance and the mains power supply.

The use of these buttons is explained with the help of Figure 5.4. This figure shows the main menu. See also chapter’8 Main menu’.

The navigation buttons are:

Buttons UP Hand DOWN L;

Enter: E;

Reset button: R

The arrows ^ and È indicate that you can scroll up and/or down. Use buttons H and Lto scroll.

The cursor » points to the option to be activated. In the display as shown in Figure 5.4 you can scroll through the main menu.

The main menu consists of: OFF, ON, WEEK PROGRAM, EXTRA PERIOD and SETTINGS. The options EXTRA PERIOD and SETTINGS only become visible after scrolling downwards.

The selected option is confirmed using E.

With the Rbutton, you go back one page in a menu, and all options selected in the current menu are lost.

nRemark

The Rbutton is also used to reset the appliance following an error.

The PC connection is exclusively intended for technicians from A.O. Smith who can read the status and history of the appliance. These details can be important for troubleshooting and/or responding to complaints.

44

Instruction Manual BFC

Page 44
Image 44
A.O. Smith 28 30 50 60 Explanation of the icons ON/OFF switch of ThermoControl, Navigation buttons, PC connection