Release R.1.3 UK 69

10 Troubleshooting
10.1 Introduction A distinction is made between:
General errors
General errors are not reported on the display. General errors are:
- Gas smell
- Display does not light up
- Insufficient or no hot water.
- Water leakage
- Explosive ignition
Table10.1 gives a troubleshooting overview for general errors.
Displayed errors
Errors are reported on the display, as follows:
- Line 1: An error code and its short description. The code is made up
of a letter and two digits.
- Lines 2, 3 and 4: a long description, and a recommended action,
alternating every 2 seconds. See Figure 10.1 and Figure 10.2.
The displayed errors are divided into two groups:
There are various types of errors:
- LOCK OUT ERRORS
When the cause is no longer present, these errors require a reset with
the R button, before the appliance can resume running.
- BLOCKING ERRORS
These errors disappear automatically once the cause of the error has
been removed, after which the appliance resumes by itself.
Table10.2 gives a troubleshooting overview for the errors that appear on the
display.
nRemark
Footnotes referred to from within any table are shown at the bottom of the
last page of that table.
S02: SENSOR ERROR
TOP TANK
SENSOR 1
NOT CONNECTED
Figure 10.1 Possible error
S02: SENSOR ERROR
TOP TANK
CHECK TOP TANK
SENSOR
Figure 10.2 Action
gis