SCPI Command Reference 6

MEASure Subsystem

Provides programming information for the keys associated with the measurements available when you press the front- panel Measure key.

OBW Subsection

Setting Percentage (%) method of OBW

:MEASure:OBW:PERCent <para>

:MEASure:OBW:PERCent?

edit the percentage of signal power used when determining the occupied bandwidth. Press {%} to set the percentage ranging from 10.00% to 99.99%.

Setting dBc method of OBW

:MEASure:OBW:XDB <para> :MEASure:OBW:XDB?

specify the power level used to determine the emission bandwidth as the number of dB down from the highest signal point, within the occupied bandwidth span.

ACPR Subsection

Center Freq

:MEASure:ACPR:CENTer <freq>

:MEASure:ACPR:CENTer?

Sets the center frequency of the main channel power.

Main channel

:MEASure:ACPR:MAIN <freq>

:MEASure:ACPR:MAIN?

N9340A User’s Guide