Agilent Technologies N9340A manual Adjacent channel, Channel space, Main Channel Power

Models: N9340A

1 172
Download 172 pages 20.6 Kb
Page 130
Image 130

6 SCPI Command Reference

Specifies the range of integration used in calculating the power in the main channel. Use the knob and the arrow keys to set the bandwidth.

Adjacent channel

:MEASure:ACPR:ADJacent <freq>

:MEASure:ACPR:ADJacent?

Specifies the range of integration used in calculating the power in the adjacent channel. Use the knob and the arrow keys to set the bandwidth.

Channel space

:MEASure:ACPR:SPACe <freq>

:MEASure:ACPR:SPACe?

Sets the space value between the center frequency of main channel power and that of the adjacent channel power.

There are also some remote commands which are irrelative to the front- panel keys.

Main Channel Power

:MEASure:ACPR:MPOWer?

Return the main channel power of ACPR measurement.

Low Adjacent Channel Power

Return the lower adjacent channel power of ACPR measurement.

:MEASure:ACPR:LPOWer?

Upper Adjacent Channel Power

Return the upper adjacent channel power of ACPR measurement.

:MEASure:ACPR:UPOWer?

120

N9340A User’s Guide

Page 130
Image 130
Agilent Technologies N9340A manual Adjacent channel, Channel space, Main Channel Power, Low Adjacent Channel Power