Boom / Head Installation
12.Routing Boom Hoses to Pump Boom hose to pump will be routed on RH Side of tractor, They are run through sleeving material and hose support bracket (See Figure 15). The Pump hoses must be connected correctly to boom and pump. There are 2 Pump to motor hoses and 1 motor case drain return hose for a total of 3. (Note Motor Case Drain hose will be run through the Oil Cooler and then return to tank).
First is the hose with the red plastic tie the lower connection at Boom, (See Figure 14), this is the pressure supply from pump, lower connection at pump (See Figure 14) to the motor connection at the boom.
Second is hose with orange plastic tie, upper connec- tion at boom (See Figure 14). This is the Return hose from the motor upper connection at pump (See Figure 14).
Third is Hose with blue plastic tie, middle connection at boom (See Figure 14) which is case drain from motor. Hose connects to the Oil Cooler / Fan Asy mounted under tractor bolster behind hyd tank. There is short hose which will not have plastic tie that will connect to oil cooler, then goes to tank return (See Figure 16).
13.Pump Hose Routing at Tank. Hose routing at tank is shown as reference to Pump hose routing which most will already be connected when tank and pump asy is shipped from factory. All hoses you must disconnect and reconnect during pump and/ or tank asy, refer to this figure for the correct location of hose (See Figure 15).
Figure 13
Orange Tie | Red Tie |
(Top Fitting) | (Bottom Fitting) |
Hose Support |
|
Bracket |
|
| No Tie (F/ Oil Cooler | |
Figure 16 | ||
to Tank) | ||
|
|
Figure 11
Hose Support Bracket
Sleeving Material for
Hoses
Figure 12
Orange Tie
Blue Tie
Red Tie
Figure 14
Axtreme Boom (Asy. Man) 07/06 | |
© 2006 Alamo Group Inc. | Section 7 - 6 |