Valve Remote Cable Controls
6.Cable Clevis Installation. Screw the cable clevis (item 7) onto the threaded cable (item 5) until the threads are fully engaged into the clevis. If the locking nut (item 6) needs to be run further onto cable, this is OK.
7.Connect Cable Clevis to Valve Spool. The cable clevis (item 7) is retained to the valve spool (item 10) with a bolt & locknut (item 8 & 9). The valve spool will have a hole in it and two flat side for the clevis to slide onto. Slide the clevis onto valve spool until the holes in clevis align with the hole in the valve spool. Install the clevis retaining bolt & locknut , but do not tighten them at this time. Continue this with the other four cables.
8.Mark Cables For Identification. The cable Will be run up through the floor of the tractor (See Figure
4as an Example, actual routing may vary). It is recommended that the ends of the cables be marked before this is done to track which cable is which control function. Cable need to be marked as shown from left to right (See Figure 5).
9.Remote Cable Control Handle. The remote control cable handle is a stackable type where they can be bolted together. All five of the handles used are the same (See Figure 6). Remove the Cable Housing Retaining screw & Nut (See Figure 6). Set the screw and nut aside for now, it will be reinstalled later.
Door/Swivel
Tilt
Dipper
Lift
Swing
Figure 5
Figure 3
Figure 4
| Remote Control |
| |
| Handle Straight Up |
| |
| In Neutral Position | Handle | |
| Remote Control | ||
| Stacking | ||
| Cable Handle Asy | Mount | |
|
|
| Holes |
| Cable Housing |
| |
| Retaining |
| |
| Screw & Nut |
| |
|
|
| Cable |
|
|
| Housing |
| Figure 6 |
| Mounting |
|
|
| Hole |
|
|
|
Axtreme Boom (Asy Man) 07/06