Valve Remote Cable Controls
13.The Arm Rest is bolted to the Control Handles. This has some options as to where it is bolted and can be bent to adjust to individual preference. (See Figure 11).
14.Control Handle Stand is bolted to the floor of the Cab under the Floor Mat on the right hand side oir to the cab support post with a fabricated bracket.. There is a rubber plug in floor under floor mat here. Remove and/or cut the rubber plug to run the cables and wire harness through it. The opening around cables through rubber plug can be sealed using silicone sealer. Floor mat will lay back down around cables and leave a small area of floor mat opening. (See Figure 11)
Figure 11
Figure 12
15.Cable Handle Control Instructional Decal. There will be a decal showing the operation of the spools of the valve that will show you how the handles shoud be placed.
13.Control Handle Adjusted to neutral position.
Adjust the cable control handle to the neutral posi- tion. Using the two locking nuts on the cable hous- ing to adjust the handle to the neutral position. Loosen one nut and tighten the other the cable can be moved back and forth in the valve mounting bracket. This must be done before operating the mover.
|
|
| Figure 13 |
| |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Axtreme Boom (Asy Man) 07/06 |
|
|
|
|
|
© 2006 Alamo Industrial | Section 8- 8 |