Appendix G-3 Commissioning QA Checklist

 

154

AOC 15/50 Commissioning Test QA Checklist

 

 

 

Turbine Number

 

 

 

Customer

 

 

 

Control Box Check

 

 

 

 

QA Check

Date

Inspect cabling to control boxes

 

 

 

Emergency Stop

 

 

 

 

QA Check

Date

Confirm function of Emergency Stop switch (MCR disabled)

 

 

 

Parking Brake release

 

 

 

 

QA Check

Date

Confirm electrical release of Parking Brake

 

 

 

(Rotor should turn if wind present)

 

 

 

NOTE: Parking brake release should produce an audible click

 

 

 

Anemometer Signal Check

 

 

 

 

QA Check

Date

W ith computer interface, check for signal from both units

 

 

 

(0-5V=0-100mph)

 

 

 

Conduct Rotor Jog

 

 

 

Confirm Directional Rotation

 

 

 

Confirm RPM (50Hz 1495-1530 and 60Hz 1790-1830)

QA Check

Date

Confirm tip brakes do not deploy

 

 

 

Dynamic Brake Test

 

 

 

Check connection of 1M and 4M wires (control wires)

 

 

 

Observe sufficient drop in RPM

QA Check

Date

(33-50% drop without tip brakes or parking brake deployed)

CAUTION: DO NOT RUN DYNAMIC BRAKE FOR LONGER THAN TEN (10) SECONDS . ALLOW RESISTORS TO COOL TO ROOM TEMPERATURE BEFORE REPEATING TEST

Placing Turbine On Line

 

QA Check

Date

Observe turbine coming on line

 

 

Manual Shutdown

 

 

Confirm turbine coming off line

QA Check

Date

Turn turbine power switch to "OFF"

 

 

Low Wind Shutdown

 

 

 

QA Check

Date

Observe low-wind shutdown.

(If conditions do not permit, simulate electrically)

QA Approval Signature

Date