Appendix |
| 154 | |
AOC 15/50 Commissioning Test QA Checklist |
|
|
|
Turbine Number |
|
|
|
Customer |
|
|
|
Control Box Check |
|
|
|
| QA Check | Date | |
Inspect cabling to control boxes |
|
|
|
Emergency Stop |
|
|
|
| QA Check | Date | |
Confirm function of Emergency Stop switch (MCR disabled) |
|
|
|
Parking Brake release |
|
|
|
| QA Check | Date | |
Confirm electrical release of Parking Brake |
|
|
|
(Rotor should turn if wind present) |
|
|
|
NOTE: Parking brake release should produce an audible click |
|
|
|
Anemometer Signal Check |
|
|
|
| QA Check | Date | |
W ith computer interface, check for signal from both units |
|
|
|
|
|
| |
Conduct Rotor Jog |
|
|
|
Confirm Directional Rotation |
|
|
|
Confirm RPM (50Hz | QA Check | Date | |
Confirm tip brakes do not deploy |
|
|
|
Dynamic Brake Test |
|
|
|
Check connection of 1M and 4M wires (control wires) |
|
|
|
Observe sufficient drop in RPM | QA Check | Date |
CAUTION: DO NOT RUN DYNAMIC BRAKE FOR LONGER THAN TEN (10) SECONDS . ALLOW RESISTORS TO COOL TO ROOM TEMPERATURE BEFORE REPEATING TEST
Placing Turbine On Line
| QA Check | Date |
Observe turbine coming on line |
|
|
Manual Shutdown |
|
|
Confirm turbine coming off line | QA Check | Date |
Turn turbine power switch to "OFF" |
|
|
Low Wind Shutdown |
|
|
| QA Check | Date |
Observe
(If conditions do not permit, simulate electrically)
QA Approval Signature
Date
NOTICE: Use of the material contained in this document is subject to the warning on page Iv and the disclaimer on page v of this document.
DOC012R02 | AOC 15/50 User Manual | Nov 2001 |