6.1.3 Maintenance commands

The CLI commands outlined in this chapter may be used to get information or perform functions which are used in a variety of situations with the ATTO iPBridge.

Date

Sets the date for the iPBridge if SNTP has been disabled or is not available.

Set syntax: set Date [MM] / [DD] / [YYYY]

Requires a SaveConfiguration command

Get syntax: get Date

FirmwareRestart

Causes the iPBridge to reboot, then re-initialize its firmware.

Immediate command: FirmwareRestart

MaxOpTemp

Establishes/reports the maximum enclosure temperature alarm in degrees Celsius. If the temperature of the iPBridge rises above the maximum MaxOpTemp, thermal control event handling occurs.

Valid entries are between 55 and 70 degrees C

Default: 70

Set syntax: set MaxOpTemp [55-70]

Requires a SaveConfiguration command

Get syntax: get MaxOpTemp

OpTempWarn

Controls the number of degrees in Celsius before a thermal control event handling occurs. Warnings will be made via system log entries. Valid entries are between 0 and 15 degrees

Default: 5

Set syntax: set OpTempWarn [0-15]

Requires a SaveConfiguration command

Get syntax: get OpTempWarn

Password

RestoreConfiguration default sets the password to the default value

Passwords are case sensitive, 1-32 characters with no spaces

When the password is all 0s, TCP/IP and ftp do not validate the password and MD5 authentication are disabled.

Default: Password

Set syntax: set Password

Requires a SaveConfiguration command

MinOpTemp

Establishes/reports the minimum enclosure temperature alarm in degrees Celsius. If the temperature of the iPBridge falls below the minimum MinOpTemp, thermal control event handling occurs. Valid entries are between 0 and 15 degrees

Default: 0

Set syntax: set MinOpTemp [0-15]

Requires a SaveConfiguration command

Get syntax: get MinOpTemp

Reserve

Reservation of the iPBridge is implicit: once the configuration image is changed by any user of services, the iPBridge becomes RESERVED. Executing a SaveConfiguration or\ Restore configuration RELEASES the iPBridge so that other services users may access it. When iPBridge services interface is RESERVED, set commands from other users are unavailable.

At least one interface must always have access to the iPBridge.

Immediate command: Reserve

RestoreConfiguration

Restores configuration to either the default configuration or the configuration last saved into non-volatile memory. The saved option will undo any changes made since the last save.

Immediate command: RestoreConfiguration [Default

Saved]

41

ATTO Technology Inc. iPBridge Installation and Operation Manual

Page 50
Image 50