Blodgett DFG-200 manual Operation, Intelliplus with Chain Event Control, Chain Event Programming

Models: DFG-100 DFG-200

1 101
Download 101 pages 32.04 Kb
Page 42
Image 42
CHAIN EVENT PROGRAMMING

3.Rotate the TEMPERATURE dial (6) to set the temperature. Operation

Intelliplus with Chain Event Control

CHAIN EVENT PROGRAMMING

NOTE: Program keys 1 and 2 can have up to six events. Program keys 3-5 can have up to

4events.

1.Press the PGM MODE ON/OFF key (13) to en- ter the programming mode. PGM will blink. The normal operation of the oven is halted.

2.Press the desired PGM # key (11) to select an event chain to be programmed. The appropri- ate PGM # will blink and remain lit. Event #1 time and temperature are shown in the dis- play. E1 is displayed alternately with the tem- perature.

3.Rotate the TEMPERATURE dial (6) to set the temperature.

4.Select LOFAN or HIFAN by pressing the COOK HI/LO FAN key (9).

5.Select FAN CON or FAN CYC by pressing the FAN CON/CYC key (12). CYC remains lit if cycling fan is selected.

6.Rotate the TIME dial (5) to set the cook time.

NOTE: If the time is set to zero (0), the event is ignored.

7.Press the EVENT # key (14). Event #2 time and temperature are shown in the display. E2 is displayed alternately with the temperature.

8.Set the desired temperature, fan speed, fan mode and time.

9.Press the EVENT # key (14) to proceed to the next event. Enter the event parameters as de- sired. If HOLD mode is desired, it must be the last event in any chain. Any events stored after a HOLD mode will be ignored.

10.To program another chain of events, press a different PGM # key (11) then press the EVENT # key (14).

11.Store as many as five (5) programs using all the PGM # keys.

12.Press PGM MODE ON/OFF (13) to exit the pro- gramming mode. PGM # disappears from the display and normal oven operation resumes.

To add new programs or to change the parame- ters of an existing program, repeat steps 1-12 as necessary.

SELECTING A PROGRAM

1.To select a program sequence, press the de- sired PGM # key (11). PGM # will be illumi- nated. At this time the oven begins to heat up to the cook temperature stored in the event #1 chain. EI is illuminated and the E1 options are displayed. The amount of time displayed is the sum total time of all the programmed events.

2.Press the START TIMER key (7) to start a pro- grammed sequence of events.

3.Press the EVENT # key (14) to display the time remaining in the current event chain. The time will remain displayed for approximately 5 sec- onds.

4.Press the ACTUAL TEMP key (8) to display the actual temperature within the oven.

5.Press the CANCEL key (15) to stop an active program sequence.

WARNING!!

A complete five minute shutdown must be observed before the oven is relighted.