Security Escort Technical Reference Manual 3.0 System Menus and Screens

EN 48

Test Differential

This is the minimum difference in receive level (1 to 255) a receiver must be less than the loudest receiver hearing a test before the green light displays acknowledging a successful test. Leave this item at default (64).

Alarm Min Level

This is the minimum receive level (1 to

255)a receiver must see before the sounder and red light is displayed for an alarm. Leave this item at default

(1).

Alarm Differential

This is the minimum difference in receive level (1 to 255) a receiver must be less than the loudest receiver hearing an alarm before the sounder and red light are displayed for an alarm. Leave this item at default (255).

Byte

These are future options, leave at default (0).

Spare

This is a future option (leave unchecked).

Test Transmitter Type

Test Receiver 1

Test Receiver 1

Transmit Delay

Transmit Point

Load Delay

Tamper Load

These parameters are used for engineering system load testing only. Do not use in a live system, as they can generate more traffic than a system can handle; therefore, actual alarms may be missed. Leave them at default.

Transponder

Selects the transponder the data is presented for.

Previous

Returns to the previous transponder in the system.

Next

Advances to the next transponder in the system.

Send Change

Sends the changes made to the selected transponder. Changes are not made to the transponder EEPROM memory unless this button is clicked.

3.3.12 Transponder Data View Screen

This screen is for engineering evaluation of a transponder only.

Figure 455: Transponder Data View Screen

Bosch Security Systems 6/12 38947D