Security Escort Technical Reference Manual 3.0 System Menus and Screens

EN 37

3.3.2 History Filter Screen

This screen selects the classes of events recorded (sent to) for specific output devices. The Select Destination box selects the History Screen, printer, history files, and system serial ports. Notice when this selection is changed, the checked items also change. There is a different set of events output for each destination selected. For each destination, the events to be output must be individually configured.

Figure 399: History Filter Screen

History Screen

This option selects the events displayed on the computer screen when Show History is selected.

Printer

This option selects the events sent to the printer.

History Archive File A

This option selects the events sent to the a_audit.txt file stored in the Security Escort sub-directory (typically C:\escort\a_audit.txt ). There is a minimum set of events that cannot be disabled, so they are always recorded.

History Archive File B

This option selects the events sent to the b_audit.txt file stored in the Security Escort sub-directory (typically C:\escort\b_audit.txt ).

System Serial Port 1

This option selects the events sent to the System Serial Port 1. System Serial Port 1 is assigned a physical comm port in the Remote Comm Port Setup Screen and the History Filter Output field must be set in the Remote Setup Screen.

System Serial Port 2

This option selects the events sent to the System Serial Port 2. System Serial Port 2 is assigned a physical comm port in the Remote Comm Port Setup Screen and the History Filter Output field must be set in the Remote Setup Screen.

Transponder Restriction

This option selects a transponder for the following restrictions:

Bosch Security Systems 6/12 38947D

Page 37
Image 37
Bosch Appliances PT-400 History Filter Screen, Printer, History Archive File a, History Archive File B, System Serial Port