Security Escort | Technical Reference Manual | 3.0 System Menus
and Screens
EN | 63
Bosch Security Systems | 6/12 | 38947D
Send Installer Demo Alarms
If checked, demo alarms are sent to the
security pager.
Send All Other Alarms
If checked, all actual alarms are sent
to the security pager.
Security Pager Confm Not Reqd
If checked, the confirmation pager
message is not sent to the security
pager when the alarm is acknowledged by
an acknowledgement transmitter.
Cancel Page If Alarm Reset
If checked, the alarm page is canceled
if the alarm is reset before it can be
communicated to the paging service.
Send Page a Second Time, 2 Minute Delay
If checked, an alarm page is sent a
second time to the security pager. Do
this in case the pager was in an area
where pages could not be heard when the
first page was sent.
Do not resend Alarm page
If checked, a pager message is sent to
the security person only once till the
alarm is cancelled or acknowledged.
Modem Init
This is the initialization string sent
to the modem to set it up for pager
communications. Normally, this setting
does not need to change. To allow
changes to this string, hold down the
[SHIFT] and [CTRL] keys when this
screen first opens. This string is
specific to each modem model. The
default setting should work with most
modems.
3.3.24 Send Pager Message Screen
Allows manually entered messages to be
sent to the service or security pagers.
Service and security pagers are
configured in the Pager Setup Screen.
Individuals and group pager assignments
are set up in the Subscriber Database.
Figure 599: Send Pager Message Screen
Enter Text to be Sent
Enter the text to be sent to the pagers
in the large text box at the top of the
screen.
Send Service
Causes the entered message to be sent
to the service pager and service pager
group.
Send Security
Causes the entered message to be sent
to the security pager and security
pager group.
Stop all Pages
Causes all pages currently queued
(automatic or manual) to be aborted and
deleted. Use with caution.
Pager Group
To send a page to all members of a
group, enter the pager group number
here (1 to 99).
Send to Group
Click this button to send the text
entered to the indicated pager group.
Select Individual
Use this drop down list to select an
individual to page.
Send to Individual
Click this button to send the text
entered to the indicated individual.
3.4 Printer Menu
The printer menu allows the alarm and
report printers to be setup and
enabled. You can also print the
contents of the history screen and
files.
Figure 600: Printer menu