Security Escort Technical Reference Manual 3.0 System Menus

and Screens

EN 53

Incoming Retried Messages

This value is number of successful receptions that indicated that they retried by the sending application. If displayed in yellow, this value is more than 1.5% of the Successful Incoming Messages.

Total Outgoing Messages

This value is total number of outgoing messages sent on this port.

Outgoing Retried Messages

This value is number of outgoing messages that were retried because the receiving application did not acknowledge them. If displayed in yellow, this value is more than 1.5% of the Total Outgoing Messages.

Receiver Buffer Max

This value is maximum number of bytes received on this serial port, but not yet processed by the system. If displayed in yellow, more than 50% of the queue was in use.

Transmit Buffer Max

This value is maximum number of bytes processed by the system, but not yet transmitted on this serial port. If displayed in yellow, more than 50% of the queue was in use.

Buffer Overflow

This is the number of times a byte was lost by the software for a serial port because the input buffer overflowed.

Bytes were placed into the input buffer faster than the system could process them.

Hardware Overrun

This is the number of times a byte was lost by the hardware for a serial port because it was not fast enough to process the byte into the input buffer.

Total Remote Access Connections

This value is the total number of times a remote access connection was successful.

Total Wrong Access Code Attempts

This value is the number of times a remote access connection was attempted and rejected because a valid remote access code was not received.

Last Remote Access Time

This is the time and date of the last successful remote access attempt.

Successful Pager Messages

This value is the number of successful pager messages sent.

Failed Pager Attempts

This value is the number of times a pager message dial-out was unsuccessful.

Reset Status

Pressing this button resets all values shown in this screen.

Refresh Data

Pressing this button refreshes all values shown in this screen. The values are not automatically updated when the screen is left open.

3.3.16System Status Screen

This screen shows the status of internal system queues and communications on the serial ports assigned to transponders.

Figure 511: System Status Screen

Maximum Retry Messages

This value is maximum number of unacknowledged messages in queue to be sent to all transponders in the system. If displayed in yellow, more than 50% of the queue was in use at this value.

Maximum Alarm Messages

This value is the maximum number of alarms that the system processed at it busiest time. If displayed in yellow, more than 50% of the maximum was in use.

Maximum Trouble Messages

This value is the maximum number of troubles in the queue yet to be displayed. If displayed in yellow, more than 50% of the queue was in use.