Security Escort Technical Reference Manual 3.0 System Menus and Screens

EN 60

Password Verify

For verification, reenter the same password as above.

Disabled

If selected, this system serial port is disabled (default).

History Filter Output

If selected, this system serial port sends out whatever items are selected in the History Filter Screen.

Video Switcher Control

If selected, this system serial port sends out the strings programmed in the Video Switcher field of the Transponder Database Edit Screen’s Area data. Also see Video Switcher Restore.

Remote System Control

If selected, this system is controlled by another system through a proprietary protocol. This setting can only be used when two systems are specifically designed to work together.

Video Switcher Restore

This string is output on any system serial port programmed for Video Switcher Control when all alarms are restored. This string is output to the video switcher to reset it to the default displays. Up to twenty characters can be entered. Control characters can be entered as [^][A] for control A.

Modem Init

This is the initialization string output to the modem to set it up for all communications except paging. Normally, this setting does not need to change. To allow changes to this string, hold down the [SHIFT] and [CTRL] keys when this screen first opens. This string is specific to each modem model. The default string should work with most modems.

Modem Reset

This is the reset string output to the modem. Normally, this setting does not need to change. To allow changes to this string, hold down the [SHIFT] and [CTRL] keys when this screen is first opened. This string is specific to each modem model. The default string should work with most modems.

3.3.21 Remote Connection Screen

This screen sets up the remote access parameters that allow remote connection to a live Security Escort System.

Figure 566: Remote Connection Screen

Set the modem port and speed in the Remote Comm Port Setup Screen. The speed selected should be greater than the speed of the modem and the same as the speed selected for the remote system. Use the Backup command under the Utilities Menu to create a database backup to floppy. In the Remote Setup Screen, assign a password and set which computer (master or slave) is to answer and the number of rings to answer on. Also copy the map file from the live Security Escort System. The map is in the Escort sub-directory and is named MAP0.EDB. There also may be other maps under the names MAP1.EDB, MAP2.EDB, and so on.