Bosch Appliances PT-400 manual Maximum Low Battery Messages, Maximum Test Strobe Messages

Models: PT-400

1 86
Download 86 pages 44.52 Kb
Page 54
Image 54

Security Escort Technical Reference Manual 3.0 System Menus and Screens

EN 54

Maximum Low Battery Messages

This value is the maximum number of transmitters with low batteries yet to be displayed. If displayed in yellow, more than 50% of the queue was in use.

Maximum Test Strobe Messages

This value is the maximum number of test strobes in use at one time. If displayed in yellow, more than 50% of the queue was in use.

Max Man Down Messages

This value is the maximum number of transmitters timing man down events, at one time. If displayed in yellow, more than 50% of the queue was in use.

Supervision Monitors

This value is the current number of transmitters being monitored for supervision transmissions.

Max Spooler Bytes

This value is the maximum number of bytes spooled for the printer at one time. If displayed in yellow, more than 50% of the queue was in use.

Max Report Spooler Bytes

This value is the maximum number of bytes spooled for the printer for Guard Tour Reports at one time. If displayed in yellow, more than 50% of the queue was in use.

Max Receiver Buffer

This value is the maximum number of bytes received from transponders on this serial port, but not yet processed by the system. If displayed in yellow, more than 50% of the queue was in use.

Max Transmit Buffer

This value is the maximum number of bytes processed by the system, but not yet transmitted to the transponders on this serial port. If displayed in yellow, more than 50% of the queue was in use.

Hardware Overrun

This is the number of times a byte was lost by the hardware for a serial port because it was not fast enough to process the byte into the input buffer.

Buffer Overflow Count

This is the number of times a byte was lost by the software for a serial port because the input buffer overflowed.

Bytes were placed into the input buffer faster than the system could process them.

Overload Level

This is a measure of the amount of time peak traffic on this serial port was greater than the system’s ability to handle it. The system automatically sheds non-essential tasks when this value rises.

Overload Count

This is a measure of the number of times peak traffic on this serial port was greater than the system’s ability to handle it. The system automatically sheds non-essential tasks when this value rises.

Reset Status

Pressing this button resets all values in this shown in this screen.

Refresh Data

Pressing this button refreshes all values shown in this screen. The values are not automatically updated when the screen is left open.

3.3.17 System Preferences Screen

The Set System Preferences Screen under the Setup Menu contains a number of settings that govern the behavior of the Security Escort System.

Figure 52: System Preferences Screen

Force Map Background Erase

Use this checkbox to erase the map screen. It should only be checked if there are problems with icons not being cleared properly from the screen; otherwise, it causes the screen to flicker.

Bosch Security Systems 6/12 38947D

Page 54
Image 54
Bosch Appliances PT-400 Maximum Low Battery Messages, Maximum Test Strobe Messages, Max Man Down Messages, Overload Level