www.bbhscanners.com 68 of 142
4. If the Detect Double Feed function operates incorrectly, adjust the sensitivity level by
selecting one of the levels in the Sensitivity drop-down list.
5. Select one of the following from the Action drop-down list:
If a Multifeed occurs, remove the document from the ADF (Automatic Document Feeder). For instructions
on removing papers jams, refer to Clearing Paper Jams in the ADF” on page58. Either separate the
multifed pages and/or reinsert the document(s) into the ADF and press the STOP/START button to resume
scanning.
High Select this when feeding thin documents.
Normal This is the standard sensitivity.
Low Select this when feeding thick documents.
Beep Signal alert
Stop Scanning Stops the scanning process for operator attention. This
is the default setting.