4.If the Detect Double Feed function operates incorrectly, adjust the sensitivity level by selecting one of the levels in the Sensitivity
High Select this when feeding thin documents.
Normal This is the standard sensitivity.
Low Select this when feeding thick documents.
5. Select one of the following from the Action
Beep | Signal alert |
|
|
Stop Scanning | Stops the scanning process for operator attention. This |
| is the default setting. |
|
|
If a Multifeed occurs, remove the document from the ADF (Automatic Document Feeder). For instructions on removing papers jams, refer to “Clearing Paper Jams in the ADF” on page 58. Either separate the multifed pages and/or reinsert the document(s) into the ADF and press the STOP/START button to resume scanning.
www.bbhscanners.com | 68 of 142 |