Symptom

Possible Cause

Remedy

 

 

 

 

 

 

 

 

The ADF glass areas.

Clean the ADF glass areas. See

 

 

Vertical lines appear on the

 

page 81.

 

 

scanned document.

 

 

 

 

The reference plates.

Clean the reference plates. See

 

 

 

 

 

 

 

page 81.

 

 

 

 

 

 

 

 

The ADF glass areas or reference

Clean the ADF glass areas and

 

 

The scanning density is

plates are dirty.

reference plates. See page 81 and

 

 

 

page 86.

 

 

uneven.

 

 

 

 

The distribution of the quantity of light

Perform the shading adjustment.

 

 

 

 

 

 

in the scan varies.

See page 130.

 

 

 

 

 

 

 

The color of the scanned

The settings of the computer display or

Adjust the computer display and monitor

 

 

document is very different

the monitor are not correct.

settings.

 

 

from the original document.

 

 

 

 

 

 

 

 

 

Dark spots or noise appear

The ADF glass areas or reference

Clean the ADF glass areas and

 

 

on the scanned documents.

plates are dirty.

reference plates. See page 81 and

 

 

 

 

page 86.

 

 

 

 

 

 

 

Scanned image has moire

This is caused by the original printing

Use the moire reduction function or

 

 

fringes or patterns, such as

pattern on the document and the

change the scanning resolution, then

 

 

stripes or wavy pattern

selected scanning resolution.

scan the document again.

 

 

noise.

 

 

 

 

 

 

 

 

 

Image crop failures with

There are unwanted objects such as

Examine and clean the reference plates.

 

 

VRS scanning.

paper or dust on the reference plates.

See page 81.

 

 

 

 

 

 

 

 

 

 

 

www.bbhscanners.com

105 of 142

Page 105
Image 105
Bowe, Bell + Howell S006830 manual 105