USER’S GUIDE
•When EAN 8, EAN 13, or UPC A is selected with the parameter “t5” or “T5”:
Ten numerical characters “0” to “9” can be accepted as bar code data.
The number of characters for bar codes is limited as follows.
EAN 8: Total 8 digits (7 digits + 1 check digit)
EAN 13: Total 13 digits (12 digits + 1 check digit)
UPC A: Total 12 digits (11 digits + 1 check digit)
A number of characters other than above causes data error and the bar code data is printed as normal print data. If the check digit is incorrect, the printer calculates the correct check digit automatically so that the correct bar code data will be printed. When EAN13 is selected, adding “+” and a
• When
The numerical characters “0” to “9” can be accepted as bar code data.
(1) | 8 digits | Standard format. The first character |
|
| must be “0” and the data must be terminated by |
|
| a check digit. |
|
| Total 8 digits = “0” + 6 digits + 1 check digit. |
(2) | 6 digits | The first character and the last |
|
| check digit are removed from the 8 digit data. |
*1: For 8 digits, “?” can be used in place of a check digit.
*2: Adding “+” and 2- or
• When Codabar is selected with the parameter “t9” or “T9”:
Characters “0” to “9”,
•When Code 128 Set A, Set B, or Set C is selected with the parameter “t12” or “T12,” “t13” or “T13,” or “t14” or “T14” respectively:
Code 128 sets A, B and C are individually selectable. Set A encodes characters Hex 00 … 5F. Set B encodes characters Hex 20 … 7F. Set C encodes numeric pairs 00 … 99. Switching is allowed between the code sets by sending %A, %B, or %C. FNC 1, 2, 3, and 4 are produced with %1, %2, %3, and %4. The SHIFT code, %S, allows temporary switching (for 1 character only) from set A to set B and vice versa. The “%” character can be encoded by sending it twice.