Port Redirect Function Screen

Source Port [n] (Selectable)

Allows a selected port [n] to be changed to a source port.

Destination Port [n] (Selectable)

Allows a selected port [n] to be changed to a destination port.

Errors (Toggle)

Allows the user to configure the source ports to either (ON) send errored frames to selected destination ports, or (OFF) drop errored frames, and send only valid traffic to the destination ports. The default setting of this field is ON. To set the Errors field, refer to Section 5.16.2

Status (Toggle)

Allows the addition or deletion of source and destination ports selected in the Source port [n] and Destination port [n] fields.

5.16.1 Displaying the Source and Destination Entries

There can be more than one Port Redirect Function screen depending on the number of port redirect entries. Each screen displays up to 10 port redirect entries. If there is more than one screen of redirect entries, the NEXT and/or PREVIOUS command displays at the bottom of the screen, allowing the user to navigate to either the next or previous screen.

For example, with three screens of entries, the NEXT command displays at the bottom of the first screen. In the second screen, the NEXT and PREVIOUS commands display. In the last screen, only the PREVIOUS command displays.

To display the next screen, use the arrow keys to highlight NEXT. Press ENTER and the next screen of entries displays.

To display the previous screen, use the arrow keys to highlight PREVIOUS. Press ENTER to view the entries in the previous screen.

2E43-51/2E43-51R User’s Guide

5-57

Page 105
Image 105
Cabletron Systems 2E43-51R manual Displaying the Source and Destination Entries