Chapter 5: Local Management

Event Message Line

 

 

 

 

 

 

2E43-51 LOCAL MANAGEMENT

 

 

 

 

Port Level Security Configuration

 

 

Module Type: 2E43-51

 

Firmware Revision:

XX.XX.XX

 

 

 

BOOTPROM Revision: XX.XX.XX

Po rt

State

Lock/Learn

Action On Intruder

 

Secure Address

1

[Secure]

[LockOnNext]

[DisablePort] [SendTrap]

 

 

2

[NonSecure]

[Unlocked]

 

[00-00-00-00-00-00]

3

[Secure]

[LockedOnAddr]

[DisablePort] [SendTrap]

[xx.xx.xx.xx.xx.xx]

4

[NonSecure]

[Unlocked]

 

[00-00-00-00-00-00]

5

[NonSecure]

[Unlocked]

 

[00-00-00-00-00-00]

6

[NonSecure]

[Unlocked]

 

[00-00-00-00-00-00]

7

[NonSecure]

[Unlocked]

 

[00-00-00-00-00-00]

8

[NonSecure]

[Unlocked]

 

[00-00-00-00-00-00]

9

[NonSecure]

[Unlocked]

 

[00-00-00-00-00-00]

10

[NonSecure]

[Unlocked]

 

[00-00-00-00-00-00]

11

[NonSecure]

[Unlocked]

 

[00-00-00-00-00-00]

12

[NonSecure]

[Unlocked]

 

[00-00-00-00-00-00]

INTERFACE #: [1]

SAVE

EXIT

 

RETURN

2251_113

Figure 5-27 Port Level Security Configuration Screen

The following section defines the fields on the Port Level Security Configuration screen.

Port (Read-only)

Indicates the repeater port on the ENET connector (ENET 1 through 4) selected in the INTERFACE # field. Refer to Table 5-5for the connector/repeater port relationship on the device.

Table 5-5 ENET/Repeater Port Relationship

ENET 1

= Repeater ports 1 – 12

ENET 3 = Repeater ports 25 – 36

 

 

 

ENET 2

= Repeater ports 13 – 24

ENET 4 = Repeater ports 37 – 48

 

 

 

State (Selectable)

Used to select the state of security for frames received by any port on the connector. The states are as follows:

Secure – Allows the ports on the connector to receive only those frames with the address as determined by the selection in the Lock/Learn field.

5-66

2E43-51/2E43-51R User’s Guide

Page 114