Removing the Chassis Cover
2E43-51/2E43-51R User’s Guide C-5
Figure C-2 2E43-51 Mode Switch Location/Component Layout
Switch definitions and positions are as follows:
Switches 1 through 4 – For Cabletron Systems use only.
Switch 5 – COM Port Autobaud. The default (OFF) position enables
Autobaud sensing on the COM port for Local Management sessions.
Changing the switch to the ON position disables Autobaud sensing and
sets the COM port to 9600 baud for Local Management sessions.
Switch 6 – Forced BootP. Do NOT attempt a Forced BootP unless a
BootP server has been configured for the 2E43-51. The BootP server
references the location of a station acting as a Trivial File Transfer
Protocol (TFTP) server containing the 2E43-51 image file. When the
position of Switch 6 is changed and the power is cycled to the
2E43-51, the device requests the image file location from the BootP
server and uses TFTP to download the image from the TFTP server. If
one of these requirements is not met, the 2E43-51 will continue to
request either the BootP server or the TFTP server until the RESET
button on the 2E43-51 is pressed. Once the RESET button is pressed,
the 2E43-51 will reset after one minute and load the image stored in
FLASH memory.
2251-05
Flash
DRAM
MODE SWITCH BANK
12345678
OFF
ON
FRONT PANEL
TOP VIEW WITHOUT COVER
Primary
Power
Supply
Redundant
Power
Supply
(2E43-51R
only)