Using LANVIEW2E43-51/2E43-51R User’s Guide 4-3
RX
(Receive)
of ENET
1 – 4 and
Ports 5
and 6
Off No link. No activity.
Port enabled or
disabled.
No error.
Green Blinking. Port
disabled. No error.
Amber Flashing. Port
enabled, activity. No error.
Red Diagnostic failure. Contact the Cabletron
Systems Global Call Center
for assistance.
TX
(Transmit)
LED of
ENET
1 – 4 and
Ports 5
and 6
Off Port enabled, and no
activity.
Should flash green
every two seconds
indicating BPDUs
being sent if STA is
enabled and there is a
valid link.
1. Ensure that the STA is
enabled and that there is a
valid link.
2. Contact the Cabletron
Systems Global Call Center
for assistance.
Green Flashing. Indicates
activity. Rate indicates
data rate.
No action.
Amber Blinking. Port in
standby.
Port may be disabled
due to Spanning Tree.
1. Ensure that the port is not
disabled.
2. Contact the Cabletron
Systems Global Call Center
for assistance.
Red Flashing. Indicates
collision rate. No action.
Solid. Diagnostic
failure. Contact the Cabletron
Systems Global Call Center
for assistance.
LINK
Ports of
ENET
1 – 4
Amber Solid. A link is
established with the
device connected to
the port.
No action.
Flashing. Link
established, but
administratively
disabled.
No action.
Off. No link. No action.
Table 4-1 LANVIEW LEDs (Continued)
LED Color State Recommended Action