Connecting to the Network

3.At the other end of the fiber optic cable, attach the SC connector to the other device.

RX LED

TX LED

2251-34

Figure 3-11 FE-100FX and FE-100F3 Ports

4.Verify that a Link exists by checking that the port RX LED is on (flashing amber, blinking green, or solid green). If the RX LED is off and the TX LED is not blinking amber, perform the following steps until the RX LED is on:

a.Check that the power is turned on for the device at the other end of the Link.

b.Verify proper crossover of fiber strands between the applicable port on the 2E43-51 and the fiber optic device at the other end of the fiber optic link segment.

c.Verify that the fiber connection meets the dB loss specifications outlined in Section 2.4.

If a Link has not been established, contact the Cabletron Systems Global Call Center. Refer to Section 1.6 for details.

2E43-51/2E43-51R User’s Guide

3-15

Page 39
Image 39
Cabletron Systems 2E43-51R manual 11 FE-100FX and FE-100F3 Ports