Chapter 5: Local Management
5-68 2E43-51/2E43-51R User’s Guide
INTERFACE # (Selectable)
This command field selects the front panel interface connector
(ENET 1 to ENET 4) to which the port security settings will be applied.
5.20.1 Setting the Port Level Security
To set the security for each repeater port on a connector, proceed as
follows:
1. Use the arrow keys to highlight the INTERFACE # field.
2. Use the SPACE bar to step to the appropriate interface connector
number (ENET 1 to ENET 4).
3. Use the arrow keys to highlight the STATE field for the interface
connector.
4. Use the SPACE bar to step to the appropriate security level (Secure or
NonSecure).
5. Use the arrow keys to highlight the Lock/Learn field for the interface
connector.
6. Use the SPACE bar to step to the appropriate type of security
(LockOnNext or LockedOnAddr).
7. If the security level chosen causes the DisablePort and SendTrap
fields to display under Action On Intruder, use the arrow keys to
highlight the DisablePort field.
If the security level chosen does not cause the fields to display under
Action On Intruder, proceed to step 11.
8. To change the DisablePort setting to NoDisable, press the SPACE
bar to toggle the setting.
9. Use the arrow keys to highlight the SendTrap field.
10. To change the setting to NoTrap, press the SPACE bar to toggle the
setting.
11. If the security state selected is LockedOnAddr, use the arrow keys to
highlight the Secure Address field for the port. Otherwise go to
step 13.
12. Enter the address to lock on.