Specifications | TechnicalSpecifications |
>"•mamV Never pick up the SmartCell
When only one power supply is installed, a sheet metal blank MUST be installed in place of the missing power supply. Failing to do so affects the fan’s air flow and may cause overheating and component failure. The blank also must be installed to maintain EMI integrity.
Table
Lamp | Meaning |
|
|
AC Power OK | The power supply is connected to AC line voltage |
|
|
DC Power OK | The power supply is producing DC power for the |
| switch |
|
|
$•• :'%+2,%"/˜96'%,),%":,329
Table
Model | SmartCell | SmartCell |
|
|
|
Processor | i960CF, 33 MHz | i960CF, 33 MHz and R4700 |
|
| 150 mhz |
|
|
|
Switching | 2.5 Gbps, | 2.5 Gbps, |
engine |
|
|
|
|
|
Switch latency | < 11 microseconds | < 11 microseconds |
|
|
|
CPU/SAR | 8 MB | 8 MB |
memory |
|
|
|
|
|
32 MB | 32 MB | |
memory |
|
|
|
|
|
Buffer memory | 32 K | 32 K |
(cells) |
|
|
|
|
|
flash memory | 8 MB | 8 MB |
|
|
|
Power supplies | Single, | Single or dual, hot swappable |
|
|
|
SmartCell