PVC Connections

Switch Administration

–•Configure the workstations for the same subnet and VPI/VCI pair = 0/101.

The broadcasting workstation on port A1 can send traffic to the receiving workstations on ports B2, B3, and C1.

4.5.3Connecting to Local Switch Client Through a PVC

All PVC connections to the SmartCell ZX-250 local clients use B4 (the CPU port) as the HighPort.

Follow these instructions to connect an end node to a SmartCell ZX-250 local client through a point-to-point PVC. s• Use add pvc to create the PVC.

SmartCell ZX # add pvc

 

 

ConnType(PTP)

:

<we use a point-to-point PVC

LowPortID()

: a1

<for this example, we connect through port a1

LowVPI()

: 0

 

LowVCI()

: 100

 

HighPortID()

: b4

<HighPort must be b4

HighVPI()

: 0

 

HighVCI()

: 100

 

FwdTrafficDescriptorIndex()

: 2

 

BkwTrafficDescriptorIndex()

: 2

 

SmartCell ZX #

¢• Use add ipatmclient to create the IP over ATM local client.

SmartCell ZX # add ipatmclient

 

 

ClientNumber(0)

: 2

<we use client # 2 in this example

ServerType(NONE)

: local

<ARP server on the switch

ServerAddress()

:

 

IPAddress()

: 10.1.1.0

NetMask(255.0.0.0)

:

 

MTU(9180)

:

 

SmartCell ZX #

 

 

••Use add ipatmpvc to associate the end node’s IP address with the PVC.

SmartCell ZX # add ipatmpvc

 

 

ClientNumber(0)

: 2

<specify local client number

DestinationIP()

: 10.1.1.22 <end node’s IP address

DestinationVPI(0)

:

 

DestinationVCI(33)

: 100

<VCI was specified as 100

SmartCell ZX #

 

 

T• Connect the end node to port A1 of the SmartCell ZX-250.

Q• Configure the end node with IP address 10.1.1.22, subnet mask 255.0.0.0, and VPI/VCI pair = 0/100.

4.5.4Non-zero VPIs

The SmartCell ZX-250 uses 12 bits to define VPI/VCI pairs. The vccmask determines how many of the 12 bits are used for the VPI and how many are used for the VCI. The vccmask uses a 2-bit register to hold four different VPI/VCI 12-bit combinations. Table 4-1shows the registers and the values that come preconfigured on the SmartCell ZX-250.

4-14 SmartCell ZX-250 User Guide