Installing the Switch

Switch Installation and Setup

If the switch’s hardware or software configuration is incorrect, contact Cabletron customer support immediately.

2.3.1DS3 and E3 I/O Module Configuration

Table 2-2shows the pre-configured values for both the DS3 (ZX-IOM-67-4) and E3 (ZX-IOM-77-4) I/O modules. These values cannot be changed. Accordingly, configure the connecting device’s interface to use these values.

Table 2-2 DS3 and E3 Module settings

Protocol

Mode

Framing

Empty Cell

Timing

Scrambling

Length

 

 

 

 

 

 

 

DS3

plcp

cbit

unassigned

internal

off

greater than 225 ft.

 

 

 

 

 

 

 

E3

plcp

G.751

unassigned

internal

off

N/A

 

 

 

 

 

 

 

2.4INSTALLING THE SWITCH

SmartCell ZX-250 switches are designed to operate either while sitting on a desktop on their rubber feet or while mounted in a rack by side-panel mounting brackets.

2.4.1Desktop Installation

ZX-250 switches can be installed on any clean, dry, stable surface (desktop) that allows for at least four inches of clear space on both sides of the switch:

UZX-250 — 17.5 inches wide by 14.5 inches deep

UZX-250r — 17.5 inches wide by 20.5 inches deep

2p›F Because the ZX-250r power supply modules install from the back of the switch, you may want to select a surface that provides sufficient room to remove and install the power supply modules.

2-4 SmartCell ZX-250 User Guide